YOKOGAWA TB450G NTU-compliant Surface Scattered Turbidity Analyzer

YOKOGAWA TB450G NTU-compliant Surface Scattered Turbidity Analyzer

The Model TB450G NTU-compliant surface scattered type turbidity analyzer has been designed to indicate turbidity in nephelometric turbidity units (NTUs), which is the unit used worldwide.

It is microprocessor-based and provides superior performance and high reliability. Moreover the improvement of the light source and the photodetecting element enables lower turbidity measurement with a resolution ten times larger than that of the existing surface scattered type turbidity analyzers. In other words, the TB450G can measure turbidity at one tenth the turbidity level that present models can detect.

 General Specification for TB450G

 User's Manual [Low Range Type]  for TB450G-L

 User's Manual [High Range Type]  for TB450G-H

Features

*

Equipped with a microprocessor, allowing provision of advanced performance and high reliability.

*

NTU turbidity unit display is available by right-angled scattering light.

*

Minimum range 0 to 0.1 NTU.

*

Enhanced self-testing functions such as detection of a disconnected lamp, a converter check, and upper and lower limit alarm.

*

Provide with multiple function such as automatic cleaning, universal-range, and automatic zero calibration.

*

Use of surface scattering light measuring method eliminates the measurement errors caused by contamination on the cell port.

*

Provide with measures against air bubbles by signal smoothig.

Specifications

Measuring method

Right-angled Surface Scattering light measuring method conforming to EPA 180.1 and ASTM D1889-88a

Measuring range

0-0.1 to 0-100 NTU, 0-10 to 0-2000 NTU

Output range

3 ranges selectable

Analog output signal

4 to 20 mA DC (Maximum load resistance 550 Ω) or 1 to 5 V DC (Output resistance 100 Ω or less)

Digital output function

RS-232C Communication

Contact output

Maintenance output, Fail output, Range output, Upper or Lower limit alarm (Default), Auto calibration / Auto cleaning (Selectable)

Contact input

Remote range switching

Automatic cleaning function 

Water jet cleaning method

Automatic calibration function

Zero-point calibration using zero water

Ambient temperature limits

-5 to 50 (Heating protection is required when water sample gets frozen in winter)

Ambient humidity limits

5 to 95 % RH (non-condensing)

Measuring water conditions

Flow rate ;       1.5 to 2 l/m
Temperature ; 0 to 50
(Ambient temperature +30)

Power supply

100/110/200/220 V AC, 50/60 Hz

Power consumption

70 VA or less (Detector and Converter)

Performance

Linearity

Low Range (-L); When the upper limit value of span is 40 NTU or less; ±2 % of the range upper limit or ±0.02 NTU, whichever is greater.
High Range (-H); When the upper limit value of span is 1000 NTU or less; ±2 % of the range upper limit

Repeatability

Low Range (-L): 2 % of the range upper limit or 0.004 NTU, whichever is greater.
High Range (-H): 2 % of the range upper limit.

Response Time

2 minutes or less (90 % response)

Application

Turbidity of drinking water, sewage water, river and water of used in general processes

#