YOKOGAWA SC8SG Conductivity Sensor

YOKOGAWA SC8SG Conductivity Sensor

Yokogawa supplies superior on-line analyzers for monitoring and controlling the conductivity of liquids and solutions.

Now, Yokogawa provides the SC450G four-wire conductivity/resistivity converter, the SC202G and SC202S two-wire conductivity/resistivity transmitters, and the SC100 panel mount conductivity converter. Yokogawa also provides many kinds of sensors for accurately measuring liquid conductivity when using converters/transmitters.

The combination of Yokogawa's converters/transmitters and sensors meets the demanding ultrapurewater requirements of the growing semiconductor and pharmacentical markets in addition to the traditional water quality measurement requirements of standard power plant and chemical applications.

The SC8SG conductivity sensor is widely used in applications such as liquid conductivity measurement for manufacturing processes and pure water resistivity measurement in the semiconductor, food, pharmaceutical, and power industries. A wide variety of mountings are available including screw-in type, flow-through type with screw joint, and flow-through type with flange.

 General Specification for Conductivity Sensors 

 User's Manual for SC8SG 

 Selection Guide for Conductivity Analyzer 

Specifications

Object of measurement

Conductivity of liquids or solutions

Measuring Principle

2-electrode or 4-electrode system

Cell Constants

0.01 cm-1 or 10 cm-1 (for 2-electrode system)
10 cm-1 (for 4-electrode system)

Measuring Ranges

0 - 0.5 μS/cm to 0 - 100 μS/cm for a cell constant of 0.01 cm-1
0 - 1 mS/cm to 0 - 1000 mS/cm for a cell constant of 10 cm-1

Temperature Range

0 to 100 deg C (130 deg C maximum only for 0.01 cm-1 cell constant detectors, excluding those with polypropylene chambers)

Pressure

1000 KPa max. (500 kPa maximum for detectors with polypropylene chambers)

Flow rate of Sample Solution

No particular limitation applies, although a value of less than 20 l/min is recommended for flow-through detectors.

RTD for Temperature Compensation

Pt1000 (built into the sensor)

Construction

Rainproof encapsulation (compatible with JIS C0920)

Weight

Screw-in: approx. 1.3 kg (without the cable)
Flow-through (SCS14 chamber): approx. 3.1 kg (without the cable)
Flow-through (SCS14 chamber, flanged): approx. 4.5 kg (without the cable)
Flow-through (polypropylene chamber): approx. 2.7 kg (without the cable)
Flow-through (polypropylene chamber, flanged): approx. 3.2 kg (without the cable)
Cable: 0.3 kg for 5.5 m length; 0.5 kg for 10 m length

Process Connection

Screw-in or flow-through

#