YOKOGAWA PH8EFP, PH8ERP, OR8EFG, OR8ERG pH/ORP Sensors |
YOKOGAWA PH8EFP, PH8ERP, OR8EFG, OR8ERG pH/ORP Sensors
Yokogawa's pH and ORP analyzers are highly reliable. They feature advanced functions and are useful for a wide variety of applications including water quality management in a broad range of production processes and in medium-sized wastewater treatment plants, or as general pH and ORP control systems.
Based on Yokogawa's track record and years of experience, a comprehensive range of products has been produced to provide solutions best suited to individual applications.
In addition to the PH8EFP, PH8ERP, OR8EFG and OR8ERG standard Ryton pH and ORP sensors, specialty pH and ORP sensors are available for various applications.
Features
Ryton pH/ORP sensors PH8EFP, PH8ERP, OR8EFG, OR8ERG
* |
With a body made of Ryton, a strong engineering plastic which is comparable to Teflon in terms of corrosion resistance and heat resistance, a wide range of applications are possible. |
* |
A single type of electrode can support all applications regardless of whether a holder or cleaner is used. |
* |
The integrated-electrode design simplifies calibration with standard solutions and maintenance. |
* |
The glass electrode of a pH analyzer, the platinum or gold electrode, and the junction of an ORP analyzer can each be easily replaced. |
Specifications
1. pH Sensors 1-1. KCl Refillable Type Electrode PH8ERP
Measured object |
Hydrogen ion concentration (pH) in aqueous solution |
Measurement principle |
Glass electrode method |
Measuring range |
pH 2 to 12 |
Measuring temperature |
-5 to 80℃ |
Measuring pressure |
Atmospheric pressure to 50 kPa |
Temperature compensation sensor |
Pt1000 |
Weight |
Approx. 0.4kg |
1-2. KCl Filling Type Electrode PH8EFP
Measured object |
Hydrogen ion concentration (pH) in aqueous solution |
Measurement principle |
Glass electrode method |
Measuring range |
pH 0 to 14 |
Measuring temperature |
-5 to 105℃ |
Measuring pressure |
Atmospheric pressure to 10 kPa (General purpose or big volume tank 500 ml) Atmospheric pressure to 500 kPa (Medium pressure) |
Temperature compensation sensor |
Pt1000 |
Weight |
Approx. 0.4 kg |
2. ORP Sensors 2-1. KCl Refillable Type Electrode OR8ERG
Measured object |
Oxidation-Reduction potential in aqueous solution |
Measurement principle |
Metal electrode method |
Measuring range |
-1500 to 1500 mV |
Measuring temperature |
-5 to 80℃ |
Measuring pressure |
Atmospheric pressure to 50 kPa |
Weight |
Approx. 0.4 kg |
2-2. KCl Filling Type Electrode OR8EFG
Measured object |
Oxidation-Reduction potential in aqueous solution |
Measurement principle |
Metal electrode method |
Measuring range |
-1500 to 1500 mV |
Measuring temperature |
-5 to 105℃ |
Measuring pressure |
Atmospheric pressure to 10 kPa (General purpose or big volume tank 500 ml) Atmospheric pressure to 500 kPa (Medium pressure) |
Weight |
Approx. 0.4kg | |
|