US300FM |
(Main Unit) (Transducer)
YOKOGAWA US300FM Ultrasonic Flowmeter
The model YOKOGAWA US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing and correlation detection method, US300FM provides fast, accurate, and no-zero offset flow measurements in clean to dirty fluids. Easy setup with interactive parameter setting. Easy adjustment with no zero-offset transducers
Ordering Examples:
1) YOKOGAWA US300FM
US300FM-GBG-NBG/TTP US300FM-GBH-NCH US300FM-GCG-NDN US300FM-GCH-NNR/TTP
2) Accessories:
USPA201 USPA221 USPA231 USPA402 USPA411 USPA001 USPA002 USPA011
USPA012 USPA021 USPA032 USPA034 USPA033 USPA054 USPA055 USPA057
USPA058 USPA073 USPA075 USPA081 USPA082 USPA091 USPA092 USPA097
USPA036 USPA053 USPA037
If you do not have complete model number, never mind, just supply us detailed parameters by email, we can choose model number and give you a quotation immediately.
Features
- More accurate measurements under difficult conditions
- New noise suppression technique improves accuracy of measurements with fluids where air bubbles are present
- Fast response
- Yokogawa signal processing technology improves the speed and accuracy of measurements
- Easy installation and adjustment of transducers
- Transducers are small and light – can be held in one hand
- Each sensor calibrated before shipment, eliminating need to tune on-site
- No longer necessary to adjust the zero flow condition
- Easy setup with interactive parameter setting process
- Two flow-input channels are provided as an option
- A maximum of two current outputs enable the simultaneous measurement of flow and sound velocity
Specifications
US300FM Performance
Fluid |
Liquid with turbidity < 10,000 mg/litter, fluid sound velocity 800 to 3,500 m/s) |
Measured values |
Volume flow, mass flow (by setting density), flow velocity, sound speed in fluid (when optional wall thickness probe is provided) |
Pipe size |
25 to 6,500 mm |
Pipe material |
Carbon steel, stainless steel, gray cast iron, ductile iron, copper, glass, PVC, etc. |
Flow velocity range |
0.01 to 25 m/s |
Fluid temperature range |
-30 deg to +130 deg C. (general use) -30 deg to +200 deg C. (high-temperature use) |
Accuracy |
1% to 3% of reading (depends on application) |
Straight pipe run upstream |
More than 10 D (depends on the piping conditions) |
Main unit construction
Housing material |
Aluminum (powder coated) |
Water/dust proof |
IP65 |
Dimensions (HxWxD) |
200 mm x 280 mm x 71 mm |
Weight |
Approx. 2.8 kg |
Transducer construction
Case material |
Stainless steel SUS316 Ti |
Water/dust proof |
IP65 (General purpose), IP67 (Immersible) |
Functions
Calculation of the two flow inputs |
Two values from an average (for two path measurement), sum, or difference for channel A and channel B inputs |
Time-programmable measurement |
Automatic start and stop of measurement using internal clock. Can be used with data logging or communication function. |
Parameter setting storage |
Storage of pipe and fluid parameters (Maximum of 80 different settings) |
Sound velocity measurement |
Measurement of the sound velocity in the liquid |
|
|