US300PM/ US300PT |
(Main Unit) (Transducer)
YOKOGAWA US300PM/ US300PT Portable Ultrasonic Flowmeter (Note: US300PM/ US300PT are discontinued, replacing new Model is FLEXIM F601, FLEXIM is the OEM of YOKOGAWA)
The model US300PM is a portable ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing and correlation detection method, US300PM provides fast, accurate, and no-zero offset flow measurements in clean to dirty fluids.
Ordering Examples:
1) YOKOGAWA US300PM:
US300PM-A02-2-N/PU1 US300PM-A13-2-N/PU2 US300PM-A23-2-N/FQ1 US300PM-A12-2-N/DLX US300PM-A03-2-N/BGT US300PM-A22-2-N/WTG US300PM-A13-2-N/WTH
2) YOKOGAWA US300PT:
US300PT-GBG-SBG/TTP US300PT-GBH-SCH US300PT-GCG-SDG/TTP US300PT-GCH-SNH US300PT-GDG-SCG/TTP
3) Accessories:
USPA301 USPA302 USPA311 USPA321 USPA322 USPA323 USPA341 USPA324 USPA325 USPA326 USPA331 USPA401 USPA402 USPA411 USPA001 USPA002
USPA011 USPA012 USPA021 USPA032 USPA034 USPA033 USPA054 USPA055
USPA057 USPA058 USPA073 USPA075 USPA081 USPA082 USPA091 USPA092
If you do not have complete model number, never mind, just supply us detailed parameters by email, we can choose model number and give you a quotation immediately.
Features: US300PM Portable Ultrasonic Flowmeter
- More accurate measurements under difficult conditions
- New noise suppression technique improves accuracy of measurements with fluids where air bubbles are present
- Fast response
- Yokogawa signal processing technology improves the speed and accuracy of measurements
- Easy installation and adjustment of transducers
- Transducers are small and light enough to hold in one hand
- Each sensor calibrated before shipment, eliminating need to tune on-site
- No longer necessary to adjust the zero flow condition
- Easy setup with interactive parameter setting process
- Two flow-input channels are provided as a standard feature
- A maximum of two current outputs enable the simultaneous measurement of flow and sound velocity
- A wall thickness measurement function is provided as a standard feature (wall thickness probes are sold separately)
- Data logging provided as a standard feature (maximum of 100,000 values)
- Data transfer function via RS232 port
- Extended battery life (maximum 14 hours)
Specifications: YOKOGAWA US300PM, YOKOGAWA US300PT Portable Ultrasonic Flowmeter
US300PM Performance
Fluid |
Liquid with turbidity < 10,000 mg/litter, fluid sound velocity 800 to 3,500 m/s) |
Measured values |
Volume flow, mass flow (by setting density), flow velocity, sound speed in fluid, pipe thickness (when optional wall thickness probe is provided) |
Pipe size |
25 to 6,500 mm |
Pipe material |
Carbon steel, stainless steel, gray cast iron, ductile iron, copper, glass, PVC, etc. |
Flow velocity range |
0.01 to 25 m/s |
Fluid temperature range |
-30 deg to +130 deg C. (general use) -30 deg to +200 deg C. (high-temperature use) |
Accuracy |
1% to 3% of reading (depends on application) |
Straight pipe run upstream |
More than 10 D (depends on piping conditions) |
Main unit construction
Housing material |
Aluminum (powder coated) |
Water/dust proof |
IP54 |
Dimensions (HxWxD) |
115 mm x 258 mm x 268 mm (without handle) |
Weight |
Approx. 3.9 kg |
Transducer construction
Case material |
Stainless steel SUS316 Ti |
Water/dust proof |
IP65 (general purpose), IP67 (immersible) |
Functions
Calculation for two flow inputs |
Two values from average (for two path measurement), sum, or difference of channel A and channel B inputs are readily available |
Time-programmable measurement |
Automatic start and stop of measurement using internal clock. Can be used with data logging or communication function. |
Parameter setting storage |
Storage of pipe and fluid parameters (maximum of 80 different settings) |
Sound velocity measurement |
Measurement of sound velocity in liquid | |
|