YOKOGAWA digitalYEWFLO High Process Temperature Version / Cryogenic Version Vortex Flowmeters
We have the process temperature version and cryogenic version in the digitalYEWFLO series which boast the long-term reliability.
The high process temperature version is available up to 450 degrees C, the highest temperature in the vortex flowmeter.
The cryogenic version is available up to -196 degrees C .
These versions are the best solutions for the high temperature steam application or the cryogenic liquid oxygen up to 200 mm of the nominal sizes.
Features: High Process Temperature Version / Cryogenic Version
New functions with Spectral Signal Processing (SSP) technology
SSP analyses the fluid conditions inside the digitalYEWFLO vortex flowmeter and uses the data to automatically select the optimum adjustment for the application, providing features never seen before in a vortex flowmeter.
SSP accurately senses vortices in the low flow range, providing outstanding flow stability.
Advanced self-diagnostics
Application conditions such as high pipeline vibration and abnormal flow are predicted and indicated
High accuracy
±0.75% of reading (liquid)
±1.0% of reading (gas, steam)
Wide process temperature range
High temperature version up to 450 deg C
Cryogenic version minimum -196 deg C
Simple parameter settings
Frequently-used selections grouped together in a quick-access format decrease commissioning time
Clear, concise indicator
Convenient display of the simultaneous and total flow rates together with the process diagnosis
Dual output for analog/pulse
Simultaneous output for flow rate and pulse
Alarm output
An alarm signal is output when an alarm occurs.
BRAIN/HART communication and key switches for human-machine interface
NACE compliant
NAMUR 43 compliant
Remote cable length up to 30m
Specifications:High Process Temp. Version / Cryogenic Version
|
Standard |
Reduced Bore |
Model & code |
DY Vortex Flowmeter |
Option code:/R1,/R2 |
Fluid to be measured |
Liquid, gas, steam (avoid multiphase flow and sticky fluids) |
Nominal size |
15mm ∼ 300mm (400mm:special) |
25mm ∼ 200mm |
Accuracy |
Liquid: |
±1.0% of reading |
|
(20000≤Re≤1000) |
Liquid: |
±0.75% of reading |
|
(D×1000≤Re) |
|
Liquid: |
±1.0% of reading |
|
(20000≤Re≤1000) |
|
Gas, steam: ±1.0% of reading (flow velocity less than 35m/s) Gas, steam: ±1.5% of reading (flow velocity 35m/s~80m/s) |
Output signal |
Simultaneous output(both analog and transistor contact output available) |
Process temperature range |
-29 deg C ∼ 260 deg C(standard) -196 deg C ∼ 100 deg C(option: cryogenic version) -29 deg C ∼ 450 deg C(option: high process temperature version) |
Process pressure limit |
-0.1MPa (-1kg/cm2) to flange rating |
Ambient temperature |
-29 to 85 deg C (Integral type / No indicator) -29 to 80 deg C (Integral type / with indicator) -29 to 85 deg C (Remote type detector) -40 to 85 deg C (Remote type converter / No indicator) -30 to 80 deg C (Remote type converter / with indicator) |
Ambient humidity |
5~100%RH( Non-condensing) |
Mounting |
Integral type and Remote type detector: Flange mounting or wafer mounting Remote type converter: 2 inch pipe mounting JIS10/20/40、ANSI150/300/600/900, JPI150/300/600,DIN PN10/16/25/40 |
Electrical connection |
JIS G1/2 female, ANSI 1/2NPT female, ISO M20×1.5 female |
Electrical classification |
JIS flameproof, FM explosion proof/intrinsically safe ATEX (CENELEC flameproof/intrinsically safe/IEC type n) CSA explosion proof/intrinsically safe : Dual Seal SAA flame proof/intrinsically safe |
Material |
Body: SCS14A cast stainless steel (equivalent to SUS316,CF8M) Shedder bar: duplex stainless steel (option:anti-corrosion version) Gasket: SUS316 stainless steel with polytetrafluoroethylene (Teflon) coating Converter housing and case cover: aluminum alloy or ASTM CF8M (equiv. JIS SCS14A) (Option: /E1) |
Applicable Standard |
*EMC Conformity Standards: EN61326-1 Class A, Table 2 (For use in industrial locations), EN61326-2-3 EN55011 Class A Group 1 *Pressure Equipment Directive: Notified Body Identification Number 0038 Module H |