SE |
YOKOGAWA ADMAG SE Series
The ADMAG SE electromagnetic flowmeter is Safe and Easy to install, operate and maintain. Its convenient field-proven design and advanced technology make for a more efficient and profitable operation.
ADMAG SE is a cost effective, wide-use magnetic flowmeter that continues to use the highly-reliable construction of the ADMAG AM, AE series.
ADMAG SE is equipped with a dual cavity housing providing ease of wiring while isolating the electronics from the environment. It is also prepared with HART or BRAIN communication as standard and its light weight makes installation easy.
Features
- High Reliability
- Based on Field Proven Technology
- Proven Construction
- Long Term Durability
- Compliance to World Market Requirements
- General Safety
- CE mark, C-Tick mark
- Explosion Proof
- ISO Standard
- High Accuracy (0.5% of flow rate)
- Easy Operation and Maintenance
- Parameter Setting with Touch Control
- Self Diagnostics
- Light Weight and Easy Installation
- Face to Face Length conform to ISO Standard(Flange Type)
- Easily Visible Display
- The large Visible LCD Panel
- Communication Capability
- HART or BRAIN as standard
- Cost-effective
Note:HART is a registered trademark of the HART Communication Foundation.
Specifications
SE Integral Type
|
SE100 |
SE200 |
Size (mm) |
15 |
25 to 200 |
Excitation |
Pulsed DC |
Flow Span (m/s) |
0.3 to 10 |
Min. Fluid Conductivity (μS/cm) |
5 |
Protection |
IP67, NEMA4X, JIS C0920 watertight type |
Hazardous Area Classification |
CENELEC(ATEX Directive), FM |
Accuracy |
0.5 % of flowrate |
Repeatability |
0.1% of flowrate (min. 1mm/s) |
Lining Material |
Fluorocarbon PFA |
Electrode Material |
SUS316L, HastelloyC-276 equivalent, Titanium, Tantalum, Pt-Ir, Tungsten Carbide |
Fluid Press. |
-0.1 to 4MPa : Size 15mm to 50mm -0.1 to 2MPa : Size 80mm to 200mm |
Fluid Temp. |
-40 to 130 deg C |
Process Connection |
DIN PN10/16/40, ANSI150/300, JIS10K/20K/F12 : Wafer or Flange |
Output Signal |
Current Output (4 to 20mA DC), Transistor Contact Output(Pulse, Alarm or Status) |
Communication |
HART or BRAIN |
Function |
Forward and Reverse Flow Measurement, Automatic Two Range Switching, Alarm Output at Low Flow Limit(Flow Switch), Totalization Switch Output |
Indicator |
6 seg. LCD with Infrared Setting Switches |
Power Supply Voltage |
80 to 127V AC or 90 to 110V DC, 180 to 264V AC, 20.4 to 28.8V DC/AC |
Maximum Power Consumption |
10W |
SE Flow Tube
|
SE100 |
SE200 |
SE300 |
Size (mm) |
15 |
25 to 200 |
250 to 400 |
Excitation |
Pulsed DC |
Flow Span (m/s) |
0.3 to 10 |
Min. Fluid Conductivity (μS/cm) |
5 |
Protection |
IP67, NEMA4X, JIS C0920 Water Tight Type |
- |
Hazardous Area Classification |
CENELEC(ATEX Directive) |
- |
Accuracy |
0.5 % of flowrate |
Repeatability |
0.1% of flowrate (min. 1mm/s) |
Lining Material |
Fluorocarbon PFA |
Electrode Material |
SUS316L, HastelloyC-276 equivalent, Titanium, Tantalum, Pt-Ir, Tungsten Carbide |
Fluid Press. |
-0.1 to 4MPa : Size 15mm to 50mm -0.1 to 2MPa : Size 80mm to 400mm |
Fluid Temp. |
-40 to 160 deg C |
Process Connection |
DIN PN10/16/40, ANSI150/300, JIS10K/20K/F12 : Wafer or Flange |
SE SE14 Flow Converter
Output Signal |
Current Output (4 to 20mA DC), Transistor Contact Output(Pulse, Alarm or Status) |
Communication |
HART or BRAIN |
Function |
Forward and Reverse Flow Measurement, Automatic Two Range Switching, Alarm Output at Low Flow Limit(Flow Switch), Totalization Switch Output |
Indicator |
6 seg.LCD with Infrared Setting Switches |
Protection |
IP67, NEMA4X, JIS C0920 Water Tight Type |
Hazardous Area Classification |
CENELEC(ATEX Directive) |
Power Supply Voltage |
80 to 127V AC or 90 to 110V DC, 180 to 264V AC, 20.4 to 28.8V DC/AC |
Maximum Power Consumption |
11W |
Mounting |
2-inch pipe mounting | |
|