CA Series |
YOKOGAWA ADMAG CA Series Magnetic Flowmeters
The YOKOGAWA ADMAG CA magnetic flowmeter adopts a system to pick up the electromotive force generated in a fluid by electrodes provided outside a ceramic pipe through the capacitance of the pipe. In addition, the flowmeter employs a prominent high-frequency excitation method that reduces flow noise in low conductivity fluid.
ADMAG CA series general specifications
Ordering Examples:
YOKOGAWA CA115SG-CB1-NSA-A1DH YOKOGAWA CA202SG-CB2-NSM-D1DH YOKOGAWA CA204SG-CK1-NSJ-A1DV YOKOGAWA CA205SG-CK2-NSD-D1DV YOKOGAWA CA208SG-CE2-NSA-A1N YOKOGAWA CA210SG-CH1-NSM-D1N YOKOGAWA CA215SG-CB1-NSJ-A1DH YOKOGAWA CA220SG-CB2-BSA-D1DV
If you do not have complete model number, never mind, just supply us detailed parameters by email, we can choose model number and give you a quotation immediately.
Features
- Ultra-low conductivity fluid measurement
Capacitance type electrodes and very high impedance head amplifier of ADMAG CA make ultra-low conductive fluid measurement possible. High-frequency excitation reduces the effects of flow noise.
- Adhesive fluid measurement
Non-wetted electrodes solve the measurement problem of sticking insulating material.
- Slurry fluid measurement
Non-wetted electrodes are free from electric noise resulting from slurry colliding with the electrodes. Stable measurement in highly concentrated slurry fluids is possible.
- High accuracy, +/- 0.5% of flow rate for ultra-low conductivity
For measurement of fluids with minimum conductivity of 0.1 microS/cm.
- Maintenance-free
No adhesion, corrosion, or clogging greatly reduces maintenance costs. ADMAG CA is ideal for processes that used to need regular cleaning.
- 150 mm and 200 mm sizes
ADMAG CA is the first* ceramic capacitance type magnetic flowmeter in the world that supports 150 mm and 200 mm sizes, for even greater flexibility in applications.
*: As of September 29, 1999.
YOKOGAWA ADMAG CA Specifications
|
CA100/200 |
Size (mm) |
15-100 |
150, 200 |
Excitation |
High frequency |
Flow span (m/s) |
0.5-10 |
Min. fluid conductivity (µS/cm) |
0.01 |
1 |
Protection |
IP67, NEMA4X, JIS C0920 watertight type |
Hazardous area classification |
FM, CSA, TIIS(JIS) |
- |
Accuracy |
±0.5% of flowrate (0.1 µS/cm min.) |
±1% of flowrate (1 µS/cm min.) |
Repeatability |
± 0.1% of flowrate (1 mm/s min.) |
Lining material |
Ceramic |
Electrode Construction |
Non-wetted plate electrodes installed on outside of ceramic tube |
Fluid pressure |
-0.1 MPa to 4 MPa: Ceramic lining size 50 mm or smaller -0.1 MPa to 2 MPa: Ceramic lining size 80 mm or greater |
Fluid temperature |
-10 deg C to 120 deg C |
Process connection |
JIS 10K/20K/F12, ANSI 150/300, DIN PN10/16: Wafer |
Output signal |
4-20 mA DC, pulse, or alarm (transistor contact: 30 V DC, 200 mA max.) |
Function |
Variable damping time (1 sec min.), self-diagnostics, loop test, BRAIN communication |
Indicator |
7-seg. LCD with back light |
Power supply voltage |
80-264 V AC/47-63 Hz or 100-130 V DC, 20.4-28.8 V DC |
Maximum power consumption |
14 W | |
|