HT INDUSTRIAL AUTOMATION LIMITED

 
PROUDCTS:Home > Proudcts > Flowmeter
RCC







YOKOGAWA ROTAMASS 3-Series Coriolis Mass Flowmeters


(RCCT34, RCCT36, RCCT38, RCCT39, RCCT39/IR, RCCT39/XR, RCCS30 RCCS31 RCCS32 RCCS33 RCCS34 RCCS36 RCCS38 RCCS39 RCCS39/IR RCCS39/XR)

RCCF31 Remote field-mount converter       to be connected to RCCS3

RCCR31 Remote converter for 19´´ rack mounting to be connected to RCCS3

RCCY031, RCCY032, RCCY033, RCCY034 Remote Cable


ROTAMASS is the integral and remote type Coriolis Mass Flowmeter. Both types have highly refined digital signal processing electronics, so that accurate and stable mass flow measurement is achieved.

ROTAMASS employs a flame-proof type converter case suitable for use in the hazardous area together with its intrinsically safety type detector.

ROTAMASS's signal processing, housing protection and its detector's special decoupling system against external loads and vibrations, realize high performance in real applications.

Supports HART, FOUNDATION™ fieldbus, Modbus


ROTAMASS 3 Series General Specifications

ROTAMASS 3 Series Coriolis Mass Flow and Density Meter User's Manual

 


Ordering Examples:

RCCT38-AH1M08A2SL/KF1/FB

RCCF31-AH2M/FB/KF4/NC

RCCY031-01-L010/KS1

RCCS30-M01A2SHKS1/P6/P8

RCCS39-IR-M15A2SL/KS1/GA/P8

RCCS34-A02A1SL/KS1/BG/HT/K6/T2

RCCF31-DH2A/KF2/BG/AD2/IE1

RCCY033-0-L005

RCCS36-A04A1SL/KS1/BG/HT/K6/T2

RCCS34-A02A1SL/KS1/BG/HT/K6/T2

RCCS39-A08A1SL/KS1/BG/MT/K6/T2

RCCS38-A04A1SL/KS1/BG/MT/K6/T2

RCCS36-A04A1SL/KS1/BG/HT/K6/T2

RCCS36-A04A1SL/KS1/BG/HT/K6/T2

RCCS36-A04A2SL/KS1/BG/HT/K6/T2

……………………………………………


Features

Field transmitter for nearly all fluids

Refined digital signal processing enables accurate and stable measurement

High accuracy and high stability over a wide range

A special detector coupling system makes the device highly independent from external loads or vibrations

Wide temperature range -200 deg C to 350 deg C


Specifications

Refined digital signal processing enables accurate and stable measurement

Simple flow path means self-draining, food capable and simple to clean

High accuracy and high stability over a wide range

-

Accurate density measurement, up to +/- 0.5 g/l

Two analog outputs, 2 pulse outputs or status-out and one status-in as standard I/O

-

Available in Explosion Proof versions

-

Wide temperature range -200 deg C to 350 deg C

-

Microprocessor-based multifunction capability

-

EEPROM protects parameter settings and totalized values

-

During power failure of any duration

-

High visibly LCD display

-

HART communication function

-

FOUNDATION™ fieldbus communication as an option

-

Modbus communication as an option

-

Intrinsically safe outputs as an option

-

Several tube materials available

-

EN or ANSI flanges as standard

-

Other process connections on request

#
copyright 2009-2021  HT INDUSTRIAL AUTOMATION LIMITED