YOKOGAWA Daqstation® CX1000/CX2000 Paperless Recorder


Control and Measurement Station
CX defines the next generation in process control by fusing recording, control and networking into a single, compact product.


Ordering Examples:


CX1000-1-0-2: DAQSTATION CX1000 (Embedded loop: 0 loop, Measurement channel: 0 ch)

CX1006-1-1-2: DAQSTATION CX1000 (Embedded loop: 0 loops, Measurement channel: 6 ch)

CX1200-1-2-2: DAQSTATION CX1000 (Embedded loop: 2 loops, Measurement channel: 6 ch)

CX1206-2-0-2: DAQSTATION CX1000 (Embedded loop: 2 loops, Measurement channel: 6 ch)

CX1000-2-1-2: DAQSTATION CX1000 (Embedded loop: 0 loop, Measurement channel: 0 ch)

CX1006-2-2-2: DAQSTATION CX1000 (Embedded loop: 0 loops, Measurement channel: 6 ch)

CX1200-3-2-2: DAQSTATION CX1000 (Embedded loop: 2 loops, Measurement channel: 6 ch)

CX1206-3-0-2: DAQSTATION CX1000 (Embedded loop: 2 loops, Measurement channel: 6 ch)

CX1206-3-1-2: DAQSTATION CX1000 (Embedded loop: 2 loops, Measurement channel: 6 ch)

CX2000-1-0-2: DAQSTATION CX2000 (Embedded loop: 0 loop, Measurement channel: 0 ch)

CX2010-1-1-2: DAQSTATION CX2000 (Embedded loop: 0 loops, Measurement channel: 10 ch)

CX2020-1-2-2: DAQSTATION CX2000 (Embedded loop: 0 loops, Measurement channel: 20 ch)

CX2200-2-0-2: DAQSTATION CX2000 (Embedded loop: 2 loops, Measurement channel: 0 ch)

CX2210-2-1-2: DAQSTATION CX2000 (Embedded loop: 2 loops, Measurement channel: 10 ch)

CX2220-2-2-2: DAQSTATION CX2000 (Embedded loop: 2 loops, Measurement channel: 20 ch)

CX2410-3-0-2: DAQSTATION CX2000 (Embedded loop: 4 loops, Measurement channel: 10 ch)

CX2420-3-1-2: DAQSTATION CX2000 (Embedded loop: 4 loops, Measurement channel: 20 ch)

CX2610-3-2-2: DAQSTATION CX2000 (Embedded loop: 6 loops, Measurement channel: 10 ch)

CX2620-1-0-2: DAQSTATION CX2000 (Embedded loop: 6 loops, Measurement channel: 20 ch)


Options:


/A6:
Measurement alarm (6 DO )

/A6R: Measurement alarm (6 DO, 8 DI)

/A4F: Measurement alarm (4 DO, FAIL/memory end detection and output )

/A4FR: Measurement alarm (4 DO, 8 DI, FAIL/memory end detection and output )

/BT1: Batch header function

/CST1: Control-purpose extension DIO (12 DI,12 DO terminals)

/D5: VGA output

/M1: Computation functions (including report functions)

/N2: Three legs isolated RTD

/P1: 24 V DC/AC power supply

/TPS4: 24 V DC transmitter power supply (4 loops)

/PG1: Program control (number of program patterns; 4)

/PG2: Program control (number of program patterns; 30)


Optional Accessories:


Shunt resister (for screw input terminal): 415920, 415921, 415922

3.5-inch floppy disk: 705900

Zip disk: A1053MP

CompactFlash memory card (CF + Adapter): B9968NL

Mounting bracket: B9900BX


Standard Specifications


Construction

Angle of mounting: Backward tilt of up to 30°; no tilt is allowed on either side, however.

Thickness of mounting panel: 2 to 26 mm

Material: Case = Steel plate, Bezel = Polycarbonate

Color of coating: Case = Pale cobalt blue (equivalent to DIC 16 edition 102)

Bezel = Light charcoal gray (equivalent to Munsell 10B3.6/0.3)

Front panel: Dust- and drip-proof (compliant to IEC529-IP65, NEMA No. 250 Type 4 [except for icing tests])

CONTROL FUNCTIONS

Control mode: Select from three control modes, i.e., single loop, cascade control, and loop control with PV switching.

Note) The control mode is fixed to single loop control for loops 5 and 6.

Control computation functions:

Continuous PID control, relay on/off control, time proportional PID control

Setting Ranges of Control Parameters

Proportional band: 0.1 to 999.9%

Integral time: 0 to 6000 sec

Derivative time: 0 to 6000 sec

On-off control hysteresis wideth: 0.0 to 100.0% of measurement range

Preset output value: -5.0 to 105.0% of output

(Provided in case of control computation being stopped, PV input being in a burnout state, or instrument input being abnormal)

Output limiter: Setting range: -5.0 to 105.0% for both high/low limits

Shutdown function: Can provide a manipulated output of up to 0 mA when in manual mode operation with 4–20 mA output (shuts down the output for values smaller than -5.1%).

Output rate-of-change limiter: Off, or a value from 0.1 to 100.0%/sec

ALARM FUNCTIONS

Control Alarm

Types of control alarm: PV high limit, PV low limit, high limit of deviation, low limit of deviation, deviation within high and low limits, SP high limit, SP low limit, OUT high limit, and OUT low limit

Other alarm type: Fault diagnosis, fail output

Stand-by action: Turns off PV/SP alarm from starting control until steady condition

Alarm output: 6 points/ 2 loops (transistor output 4 points, relay output 2 points)

Alarm setting: 4 types/ loop

Hysteresis: Can set each alarm setting

Display: The status is shown in the digital display in case of alarm. A common alarm

indication is also displayed. The alarm behavior: non-hold or hold-type can be selectable for common to all channels

Measurement Alarm

Types of alarm: High limit, low limit, differential high limit, differential low limit, high limit of rate-ofchange,

low limits of rate-of-change, high limit of delay, and low limits of delay (alarm delay)

Alarm delay time: 1 to 3600 sec (1 hr)

Time interval of rate-of-change alarm: Measuring interval × 1 to 15

Alarm output: 6 points (option) *alarm output can be assigned to control output

Number of setting: Max. 4/ each channel

Hysteresis: ON (0.5% of span)/ OFF selectable (common to all channels and all levels)

Display: The status is shown in the digital display in case of alarm. A common alarm indication is also displayed. The alarm behavior: non-hold or hold-type can be selectable or common to all channels

INPUT SECTION

Specifications Common to Control and Measurement Inputs

Thermocouple burnout:Switchable between ON/OFF options of detection on a channel basis.

Switchable between burnout upscale/downscale options

Integral time of Select from the options of 20 ms (50 Hz), 16.7 ms (60 Hz) and AUTO

A/D converter: (automatic switching between 20 ms and 16.7 ms depending on the power supply frequency).

Control Input

Input interval: 250, 500 or 1000 ms, synchronized with the control period

Input type: DC voltage (DCV), thermocouple (TC), resistance temperature detector (RTD),

DC current (DCA) with external shunt resistor

YOKOGAWA CX1000 Paperless Recorder

YOKOGAWA CX1006 Paperless Recorder

YOKOGAWA CX1200 Paperless Recorder

YOKOGAWA CX1206 Paperless Recorder

YOKOGAWA CX2000 Paperless Recorder

YOKOGAWA CX2010 Paperless Recorder

YOKOGAWA CX2020 Paperless Recorder

YOKOGAWA CX2200 Paperless Recorder

YOKOGAWA CX2210 Paperless Recorder

YOKOGAWA CX2220 Paperless Recorder

YOKOGAWA CX2410 Paperless Recorder

YOKOGAWA CX2420 Paperless Recorder

YOKOGAWA CX2610 Paperless Recorder

YOKOGAWA CX2620 Paperless Recorder

#
copyright 2009-2021  HT INDUSTRIAL AUTOMATION LIMITED