YOKOGAWA INSTRUMENT CURRENT TRANSFORMERS |
YOKOGAWA INSTRUMENT CURRENT TRANSFORMERS
Instrument transformer is a general term for voltage transformers and current transformers that are used with electrical instruments. The main purpose of instrument transformers is to extend the measurement range for electrical quantities (voltage, current, power, power factor) on large-current and high-voltage circuits. They serve to convert currents and voltages to levels that are suitable for measurement, and to insulate the instrument, etc. from high-voltage circuitry. YOKOGAWA makes a variety of standard instrument transformers. These include the top class (Class 0.1) current transformer 2243, the Class 0.2 6600V circuit instrument voltage transformer 2262, the 6600V current transformer 2242, instrument voltage transformer 2261, and current transformer 2241.
Specifications - Model 2241 00
|
Conversion Type |
Current |
|
Current |
0.5 ~ 1500 A |
|
Primary |
10/15/30/50/100/ 250/300/500/750/1500A |
|
Secondary |
5A |
|
Rated Load |
15 VA |
|
Relative Error |
± 0.2% |
|
Phase Angle |
± 10 minutes |
|
Class |
JIS C 1731 : 1997 Class 0.2 |
|
Maximum Circuit Voltage |
3450 V |
|
Withstand Voltage |
10000 V |
|
Rated Frequency |
50 ~ 60 Hz |
|
Approx. External Dimension |
318 x 246 x 128 mm |
|
Approx. External Weight |
9 kg |
Features
- Precision conversion of electrical quantities on AC large-current or high-voltage circuits
- Secondary circuit is isolated from primary circuit.
- Capable of wide-range measurement using numerous ranges
Specifications - Model 2242 00
|
Conversion Type |
Current |
|
Current |
0.5 ~ 1500 A |
|
Primary |
10/15/30/50/100/ 250/300/500/750/1500A |
|
Secondary |
5A |
|
Rated Load |
15 VA |
|
Relative Error |
± 0.2% |
|
Phase Angle |
± 10 minutes |
|
Class |
JIS C 1731 : 1997 Class 0.2 |
|
Maximum Circuit Voltage |
6900 V |
|
Withstand Voltage |
16000 V |
|
Rated Frequency |
50 ~ 60 Hz |
|
Approx. External Dimension |
349 x 267 x 152 mm |
|
Approx. External Weight |
11 kg |
Features
- Precision conversion of electrical quantities on AC large-current or high-voltage circuits
- Secondary circuit is isolated from primary circuit.
- Capable of wide-range measurement using numerous ranges
Specifications - Model 2243 00
|
Conversion Type |
Current |
|
Current |
0.5 ~ 1500 A |
|
Primary |
0.5/0.75/1/1.5/2/ 3/5/7.5/10/15/20/30/50/75/100A |
|
Secondary |
5A |
|
Rated Load |
15 VA |
|
Relative Error |
± 0.1% |
|
Phase Angle |
± 5 minutes |
|
Class |
JIS C 1731 : 1997 Class 0.1 |
|
Maximum Circuit Voltage |
250 V |
|
Withstand Voltage |
2000 V |
|
Rated Frequency |
50 ~ 60 Hz |
|
Approx. External Dimension |
343 x 256 x 136 mm |
|
Approx. External Weight |
12.5 kg |
Features
- Precision conversion of electrical quantities on AC large-current or high-voltage circuits
- Secondary circuit is isolated from primary circuit.
- Capable of wide-range measurement using numerous ranges
Specifications - Model 2261 01
|
Conversion Type |
Voltage |
|
Voltage |
15 ~ 6600 V |
|
Primary |
220/440/2200/3300V |
|
Secondary |
110V |
|
Rated Load |
15 VA |
|
Relative Error |
± 0.2% |
|
Phase Angle |
± 10 minutes |
|
Class |
JIS C 1731 : 1997 Class 0.2 |
|
Withstand Voltage |
10000 V |
|
Rated Frequency |
50 ~ 60 Hz |
|
Approx. External Dimension |
255 x 240 x 200 mm |
|
Approx. External Weight |
18 kg |
Features
- Precision conversion of electrical quantities on AC large-current or high-voltage circuits
- Secondary circuit is isolated from primary circuit.
- Capable of wide-range measurement using numerous ranges
Specifications - Model 2262 00
|
Conversion Type |
Voltage |
|
Voltage |
15 ~ 6600 V |
|
Primary |
3300/6600V |
|
Secondary |
110V |
|
Rated Load |
15 VA |
|
Relative Error |
± 0.2% |
|
Phase Angle |
± 10 minutes |
|
Class |
JIS C 1731 : 1997 Class 0.2 |
|
Withstand Voltage |
16000 V |
|
Rated Frequency |
50 ~ 60 Hz |
|
Approx. External Dimension |
294 x 240 x 200 mm |
|
Approx. External Weight |
18 kg |
Features
- Precision conversion of electrical quantities on AC large-current or high-voltage circuits
- Secondary circuit is isolated from primary circuit.
- Capable of wide-range measurement using numerous ranges
SHUNTS
Specifications - Model 2215 08
|
Rating |
15A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2215 09
|
Rating |
20A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2215 10
|
Rating |
30A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2215 11
|
Rating |
50A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2215 12
|
Rating |
75A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2215 13
|
Rating |
100A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2215 14
|
Rating |
150A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2215 15
|
Rating |
200A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2215 16
|
Rating |
300A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2216 01
|
Rating |
500A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2216 02
|
Rating |
750A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2216 03
|
Rating |
1000A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2217 01
|
Rating |
1500A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2217 02
|
Rating |
2000A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2217 03
|
Rating |
3000A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2217 04
|
Rating |
5000A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
± 0.2% |
Specifications - Model 2215 07
|
Rating |
10A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
+/-0.2% |
Specifications - Model 2215 01
|
Rating |
1A |
|
Rated Voltage Drop |
50 mV |
|
Tolerance |
+/-0.2% |
EXTERNAL MULTIPLIERS
Specifications - Model 2222 01
Specifications - Model 2222 02
Specifications - Model 2222 03
Specifications - Model 2223 00
2291 AND 2292 CARRYING CASES
Carrying cases are useful for carrying and storing instruments.
Specifications - Model 2291 01
|
Compatible Instruments |
2011, 2013, 2016 (voltmeters), 2017, 2038 |
Specifications - Model 2292 01
|
Compatible Instruments |
2012, 2014, 2016 (ammeters), 2039, 2041, 2042, 3254 |
Specifications - Model 2291 02
|
Compatible Instruments |
2051, 2052, 2053 | |
|