Model 2039 is a revolutionary series of portable wattmeters in which a power factor is used to operate the DC indicator. This is done using a transducer which provides a DC current proportionate to the voltage-current phase by means of a circuit. Model 2039 can be used in single-phase and balanced three-phase circuits. The electronic transducer, combined with a high sensitivity moving coil type indicator based on YOKOGAWA's proprietary taut-band suspension system, provides a level of performance not possible with conventional power factor meters.

Specifications - Model 2039 01

Rated Current

0.2/1 A

Rated Voltage

120V (Used between 60 and 300 V.)

Operating Principle

Rectifier type

Class

JIS C 1102 : 1997 Class 3.0

Operating Position

Horizontal

Rated Frequency

45 ~ 65 Hz

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale

Lead 0-0.3 to 1.0 to 0.3-0 lag (with phase angle scale)

Effective Measurement Range

Lead 0.5 to 1.0 to 0.5 lag

Approx. Consumed Power Voltage Circuit (120 V)

0.14 VA

Approx. Current Circuit (5 A)

2.4 VA

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 115 mm

Approx. External Weight

2.9 kg

Optional Accessories

2292 01 Carrying case

Features

  •  
    • For both single-phase and three-phase (balanced circuit).
    • Excellent current characteristic: 20 ~ 200% of rated current (short time period)
    • Wide range of applicable voltages: 60 ~ 300 V AC
    • Phase angle scale included
    • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

Specifications - Model 2039 02

Rated Current

1/5A

Rated Voltage

120V (Used between 60 and 300 V.)

Operating Principle

Rectifier type

Class

JIS C 1102 : 1997 Class 3.0

Operating Position

Horizontal

Rated Frequency

45 ~ 65 Hz

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale

Lead 0-0.3 to 1.0 to 0.3-0 lag (with phase angle scale)

Effective Measurement Range

Lead 0.5 to 1.0 to 0.5 lag

Approx. Consumed Power Voltage Circuit (120 V)

0.14 VA

Approx. Current Circuit (5 A)

2.4 VA

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 115 mm

Approx. External Weight

2.9 kg

Optional Accessories

2292 01 Carrying case

Features

  • For both single-phase and three-phase (balanced circuit).
  • Excellent current characteristic: 20 ~ 200% of rated current (short time period)
  • Wide range of applicable voltages: 60 ~ 300 V AC
  • Phase angle scale included
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

Specifications - Model 2039 03

Rated Current

5/25A

Rated Voltage

120V (Used between 60 and 300 V.)

Operating Principle

Rectifier type

Class

JIS C 1102 : 1997 Class 3.0

Operating Position

Horizontal

Rated Frequency

45 ~ 65 Hz

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale

Lead 0-0.3 to 1.0 to 0.3-0 lag (with phase angle scale)

Effective Measurement Range

Lead 0.5 to 1.0 to 0.5 lag

Approx. Consumed Power Voltage Circuit (120 V)

0.14 VA

Approx. Current Circuit (5 A)

2.4 VA

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 115 mm

Approx. External Weight

2.9 kg

Optional Accessories

2292 01 Carrying case

Features

  • For both single-phase and three-phase (balanced circuit).
  • Excellent current characteristic: 20 ~ 200% of rated current (short time period)
  • Wide range of applicable voltages: 60 ~ 300 V AC
  • Phase angle scale included
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

PORTABLE WATTMETERS 2041, 2042

Model 2041 single-phase wattmeters and single-phase low-power-factor wattmeters and Model 2042 three-phase wattmeters are electrodynamometer type wattmeters with indicators based on taut-band suspension. They can handle DC and frequencies from 25 Hz to 1000 Hz, and provide excellent power factor characteristics. These instruments are shielded with dual permalloy sheets as protection against external magnetic fields.

Specifications - Model 2041 01

Class

JIS C 1102: 1997 Class 0.5

Rated Voltage (Approximate Consumed Power)

120/240V (1.2/2.4 VA)

Rated Current (Approximate Consumed Power)

0.2/1 A (0.66/0.56VA)

Rated Power Factor

1.0

Operating Frequency

DC, 25~1000 Hz

Operating Principle

Electrodynamometer type

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

120

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 136 mm

Approx. External Weight

2.8 kg

Optional Accessories

2292 01 Carrying case

Features

  • Frequency range: DC, 25 Hz to 1000 Hz (2041 01-03,2042 01-03)
  • Effective for measurement of low-power-factor load power and small power (2041 11-13, 21, 22)
  • Low self-consuming power
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

Specifications - Model 2041 02

Class

JIS C 1102: 1997 Class 0.5

Rated Voltage (Approximate Consumed Power)

120/240V (1.2/2.4 VA)

Rated Current (Approximate Consumed Power)

1/5A (0.93/0.84VA)

Rated Power Factor

1.0

Operating Frequency

DC, 25~1000 Hz

Operating Principle

Electrodynamometer type

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

120

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 136 mm

Approx. External Weight

2.8 kg

Optional Accessories

2292 01 Carrying case

Features

  • Frequency range: DC, 25 Hz to 1000 Hz (2041 01-03,2042 01-03)
  • Effective for measurement of low-power-factor load power and small power (2041 11-13, 21, 22)
  • Low self-consuming power
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

Specifications - Model 2041 03

Class

JIS C 1102: 1997 Class 0.5

Rated Voltage (Approximate Consumed Power)

120/240V (1.2/2.4 VA)

Rated Current (Approximate Consumed Power)

5/25A (1.72/1.69VA)

Rated Power Factor

1.0

Operating Frequency

DC, 25~1000 Hz

Operating Principle

Electrodynamometer type

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

120

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 136 mm

Approx. External Weight

2.8 kg

Optional Accessories

2292 01 Carrying case

Features

  • Frequency range: DC, 25 Hz to 1000 Hz (2041 01-03,2042 01-03)
  • Effective for measurement of low-power-factor load power and small power (2041 11-13, 21, 22)
  • Low self-consuming power
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

Specifications - Model 2042 01

Class

JIS C 1102: 1997 Class 0.5

Rated Voltage (Approximate Consumed Power)

120/240V (1.2/2.4 VA)

Rated Current (Approximate Consumed Power)

0.2/1 A (0.66/0.56VA)

Rated Power Factor

1.0

Operating Frequency

DC, 25~1000 Hz

Operating Principle

Electrodynamometer type

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

120

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 136 mm

Approx. External Weight

3.2 kg

Optional Accessories

2292 01 Carrying case

Features

  • Frequency range: DC, 25 Hz to 1000 Hz (2041 01-03,2042 01-03)
  • Effective for measurement of low-power-factor load power and small power (2041 11-13, 21, 22)
  • Low self-consuming power
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

Specifications - Model 2042 02

Class

JIS C 1102: 1997 Class 0.5

Rated Voltage (Approximate Consumed Power)

120/240V (1.2/2.4 VA)

Rated Current (Approximate Consumed Power)

1/5A (0.93/0.84VA)

Rated Power Factor

1.0

Operating Frequency

DC, 25~1000 Hz

Operating Principle

Electrodynamometer type

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

120

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 136 mm

Approx. External Weight

3.2 kg

Optional Accessories

2292 01 Carrying case

Features

  • Frequency range: DC, 25 Hz to 1000 Hz (2041 01-03,2042 01-03)
  • Effective for measurement of low-power-factor load power and small power (2041 11-13, 21, 22)
  • Low self-consuming power
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

Specifications - Model 2042 03

Class

JIS C 1102: 1997 Class 0.5

Rated Voltage (Approximate Consumed Power)

120/240V (1.2/2.4 VA)

Rated Current (Approximate Consumed Power)

5/25A (1.72/1.69VA)

Rated Power Factor

1.0

Operating Frequency

DC, 25~1000 Hz

Operating Principle

Electrodynamometer type

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

120

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 136 mm

Approx. External Weight

3.2 kg

Optional Accessories

2292 01 Carrying case

Features

  • Frequency range: DC, 25 Hz to 1000 Hz (2041 01-03,2042 01-03)
  • Effective for measurement of low-power-factor load power and small power (2041 11-13, 21, 22)
  • Low self-consuming power
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

Specifications - Model 2041 11

Class

JIS C 1102 :1997 equivalent to Class 0.5

Rated Voltage (Approximate Consumed Power)

120/240V (2.4/4.8 VA)

Rated Current (Approximate Consumed Power)

0.2/1 A (1.25/1.09VA)

Rated Power Factor

0.2

Operating Frequency

25~500 Hz

Operating Principle

Electrodynamometer type

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

120

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 136 mm

Approx. External Weight

2.8 kg

Optional Accessories

2292 01 Carrying case

Features

  • Frequency range: DC, 25 Hz to 1000 Hz (2041 01-03,2042 01-03)
  • Effective for measurement of low-power-factor load power and small power (2041 11-13, 21, 22)
  • Low self-consuming power
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

Specifications - Model 2041 12

Class

JIS C 1102 :1997 equivalent to Class 0.5

Rated Voltage (Approximate Consumed Power)

120/240V (2.4/4.8 VA)

Rated Current (Approximate Consumed Power)

1/5A (1.7/1.5VA)

Rated Power Factor

0.2

Operating Frequency

25~500 Hz

Operating Principle

Electrodynamometer type

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

120

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 136 mm

Approx. External Weight

2.8 kg

Optional Accessories

2292 01 Carrying case

Features

  • Frequency range: DC, 25 Hz to 1000 Hz (2041 01-03,2042 01-03)
  • Effective for measurement of low-power-factor load power and small power (2041 11-13, 21, 22)
  • Low self-consuming power
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

Specifications - Model 2041 13

Class

JIS C 1102 :1997 equivalent to Class 0.5

Rated Voltage (Approximate Consumed Power)

120/240V (2.4/4.8 VA)

Rated Current (Approximate Consumed Power)

5/25A (2.62/2.5VA)

Rated Power Factor

0.2

Operating Frequency

25~500 Hz

Operating Principle

Electrodynamometer type

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

120

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 136 mm

Approx. External Weight

2.8 kg

Optional Accessories

2292 01 Carrying case

Features

  • Frequency range: DC, 25 Hz to 1000 Hz (2041 01-03,2042 01-03)
  • Effective for measurement of low-power-factor load power and small power (2041 11-13, 21, 22)
  • Low self-consuming power
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

Specifications - Model 2041 21

Class

JIS C 1102 :1997 equivalent to Class 0.5

Rated Voltage (Approximate Consumed Power)

30/60V (0.6/1.2 VA)

Rated Current (Approximate Consumed Power)

0.2/1 A (1.25/1.09VA)

Rated Power Factor

0.2

Operating Frequency

25~500 Hz

Operating Principle

Electrodynamometer type

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

120

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 136 mm

Approx. External Weight

2.8 kg

Optional Accessories

2292 01 Carrying case

Features

  • Frequency range: DC, 25 Hz to 1000 Hz (2041 01-03,2042 01-03)
  • Effective for measurement of low-power-factor load power and small power (2041 11-13, 21, 22)
  • Low self-consuming power
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.

Specifications - Model 2041 22,

Class

JIS C 1102 :1997 equivalent to Class 0.5

Rated Voltage (Approximate Consumed Power)

30/60V (0.6/1.2 VA)

Rated Current (Approximate Consumed Power)

1/5A (1.7/1.5VA)

Rated Power Factor

0.2

Operating Frequency

25~500 Hz

Operating Principle

Electrodynamometer type

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

120

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Approx. External Dimension

260 x 180 x 136 mm

Approx. External Weight

2.8 kg

Optional Accessories

2292 01 Carrying case

Features

  • Frequency range: DC, 25 Hz to 1000 Hz (2041 01-03,2042 01-03)
  • Effective for measurement of low-power-factor load power and small power (2041 11-13, 21, 22)
  • Low self-consuming power
  • Taut-band suspension system eliminates friction and provides strong resistance to shock impact.
#
copyright 2009-2021  HT INDUSTRIAL AUTOMATION LIMITED