HT INDUSTRIAL AUTOMATION LIMITED

 
YOKOGAWA PORTABLE HIGH-FREQUENCY AC AMMETERS & VOLTMETERS 2016

YOKOGAWA PORTABLE HIGH-FREQUENCY AC AMMETERS & VOLTMETERS 2016

Model 2016 consists of thermocouple type ammeters and voltmeters with four different measurement ranges. They are designed to provide true RMS values of inputs, so they can be used to measure high-frequency currents and voltages (DC) up to several MHz (the maximum frequency for the voltmeter is 100 kHz). The indicator is based on a taut-band suspension system, which eliminates friction, provides good resistance to vibrations and shock impact, and ensures excellent characteristics.

Specifications - Model 2016 01

Max. Scale Value

5/10/20/50 mA

Approximate Consumed Current

375 mV

Operating Principle

Thermocouple type Class

Class

JIS C 1102 : 1997 Class 1.0

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

100 for ammeters, 150 for voltmeter

Overload

Approximately 1.5 times rated current (or approximate consumed current)

Operating Frequency Range

10 Hz to 5 MHz

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Linemax

250 V (Ammeters only)

Approx. External Dimension

260 x 180 x 115 mm

Approx. External Weight

2.5 kg

Optional Accessories

2291 01 Carrying case for ammeters
2292 01 Carrying case for voltmeter
B964688 Spare thermocouple

Features

  • Taut-band suspension system eliminates friction and provides good resistance to shock impact.
  • For measurements (DC) up to high frequencies

Specifications - Model 2016 02

Max. Scale Value

20/50/100/200 mA

Approximate Consumed Current

375 mV

Operating Principle

Thermocouple type Class

Class

JIS C 1102 : 1997 Class 1.0

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

100 for ammeters, 150 for voltmeter

Overload

Approximately 1.5 times rated current (or approximate consumed current)

Operating Frequency Range

10 Hz to 2 MHz

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Linemax

250 V (Ammeters only)

Approx. External Dimension

260 x 180 x 115 mm

Approx. External Weight

2.5 kg

Optional Accessories

2291 01 Carrying case for ammeters
2292 01 Carrying case for voltmeter
B964688 Spare thermocouple

Features

  • Taut-band suspension system eliminates friction and provides good resistance to shock impact.
  • For measurements (DC) up to high frequencies

Specifications - Model 2016 03

Max. Scale Value

100/200/500/1000 mA

Approximate Consumed Current

375 mV

Operating Principle

Thermocouple type Class

Class

JIS C 1102 : 1997 Class 1.0

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

100 for ammeters, 150 for voltmeter

Overload

Approximately 1.5 times rated current (or approximate consumed current)

Operating Frequency Range

10 Hz to 1 MHz

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Linemax

250 V (Ammeters only)

Approx. External Dimension

260 x 180 x 115 mm

Approx. External Weight

2.5 kg

Optional Accessories

2291 01 Carrying case for ammeters
2292 01 Carrying case for voltmeter
B964688 Spare thermocouple

Features

  • Taut-band suspension system eliminates friction and provides good resistance to shock impact.
  • For measurements (DC) up to high frequencies

Specifications - Model 2016 04

Max. Scale Value

15/30/75/150 V

Approximate Consumed Current

5 mV (200 Ω/V)

Operating Principle

Thermocouple type Class

Class

JIS C 1102 : 1997 Class 1.0

Operating Position

Horizontal

Scale Length

Approximately 135 mm (Deflection Angle: 85°)

Scale Divisions

100 for ammeters, 150 for voltmeter

Overload

Approximately 1.5 times rated current (or approximate consumed current)

Operating Frequency Range

10 Hz to 1 kHz

Operating Temperature Range

0 ~ 40 ºC

Operating Humidity Range

30 ~ 75% RH

Storage Temperature Range

-10 ~ 50 ºC

Storage Humidity Range

25 ~ 80% RH

Linemax

250 V (Ammeters only)

Approx. External Dimension

195 x 170 x 87 mm

Approx. External Weight

1.8 kg

Optional Accessories

2291 01 Carrying case for ammeters
2292 01 Carrying case for voltmeter
B964688 Spare thermocouple

Features

  • Taut-band suspension system eliminates friction and provides good resistance to shock impact.
  • For measurements (DC) up to high frequencies
#
copyright 2009-2021  HT INDUSTRIAL AUTOMATION LIMITED