YOKOGAWA PORTABLE HIGH-FREQUENCY AC AMMETERS & VOLTMETERS 2016 |
YOKOGAWA PORTABLE HIGH-FREQUENCY AC AMMETERS & VOLTMETERS 2016
Model 2016 consists of thermocouple type ammeters and voltmeters with four different measurement ranges. They are designed to provide true RMS values of inputs, so they can be used to measure high-frequency currents and voltages (DC) up to several MHz (the maximum frequency for the voltmeter is 100 kHz). The indicator is based on a taut-band suspension system, which eliminates friction, provides good resistance to vibrations and shock impact, and ensures excellent characteristics.
Specifications - Model 2016 01
Max. Scale Value |
5/10/20/50 mA |
Approximate Consumed Current |
375 mV |
Operating Principle |
Thermocouple type Class |
Class |
JIS C 1102 : 1997 Class 1.0 |
Operating Position |
Horizontal |
Scale Length |
Approximately 135 mm (Deflection Angle: 85°) |
Scale Divisions |
100 for ammeters, 150 for voltmeter |
Overload |
Approximately 1.5 times rated current (or approximate consumed current) |
Operating Frequency Range |
10 Hz to 5 MHz |
Operating Temperature Range |
0 ~ 40 ºC |
Operating Humidity Range |
30 ~ 75% RH |
Storage Temperature Range |
-10 ~ 50 ºC |
Storage Humidity Range |
25 ~ 80% RH |
Linemax |
250 V (Ammeters only) |
Approx. External Dimension |
260 x 180 x 115 mm |
Approx. External Weight |
2.5 kg |
Optional Accessories |
2291 01 Carrying case for ammeters 2292 01 Carrying case for voltmeter B964688 Spare thermocouple |
Features
- Taut-band suspension system eliminates friction and provides good resistance to shock impact.
- For measurements (DC) up to high frequencies
Specifications - Model 2016 02
Max. Scale Value |
20/50/100/200 mA |
Approximate Consumed Current |
375 mV |
Operating Principle |
Thermocouple type Class |
Class |
JIS C 1102 : 1997 Class 1.0 |
Operating Position |
Horizontal |
Scale Length |
Approximately 135 mm (Deflection Angle: 85°) |
Scale Divisions |
100 for ammeters, 150 for voltmeter |
Overload |
Approximately 1.5 times rated current (or approximate consumed current) |
Operating Frequency Range |
10 Hz to 2 MHz |
Operating Temperature Range |
0 ~ 40 ºC |
Operating Humidity Range |
30 ~ 75% RH |
Storage Temperature Range |
-10 ~ 50 ºC |
Storage Humidity Range |
25 ~ 80% RH |
Linemax |
250 V (Ammeters only) |
Approx. External Dimension |
260 x 180 x 115 mm |
Approx. External Weight |
2.5 kg |
Optional Accessories |
2291 01 Carrying case for ammeters 2292 01 Carrying case for voltmeter B964688 Spare thermocouple |
Features
- Taut-band suspension system eliminates friction and provides good resistance to shock impact.
- For measurements (DC) up to high frequencies
Specifications - Model 2016 03
Max. Scale Value |
100/200/500/1000 mA |
Approximate Consumed Current |
375 mV |
Operating Principle |
Thermocouple type Class |
Class |
JIS C 1102 : 1997 Class 1.0 |
Operating Position |
Horizontal |
Scale Length |
Approximately 135 mm (Deflection Angle: 85°) |
Scale Divisions |
100 for ammeters, 150 for voltmeter |
Overload |
Approximately 1.5 times rated current (or approximate consumed current) |
Operating Frequency Range |
10 Hz to 1 MHz |
Operating Temperature Range |
0 ~ 40 ºC |
Operating Humidity Range |
30 ~ 75% RH |
Storage Temperature Range |
-10 ~ 50 ºC |
Storage Humidity Range |
25 ~ 80% RH |
Linemax |
250 V (Ammeters only) |
Approx. External Dimension |
260 x 180 x 115 mm |
Approx. External Weight |
2.5 kg |
Optional Accessories |
2291 01 Carrying case for ammeters 2292 01 Carrying case for voltmeter B964688 Spare thermocouple |
Features
- Taut-band suspension system eliminates friction and provides good resistance to shock impact.
- For measurements (DC) up to high frequencies
Specifications - Model 2016 04
Max. Scale Value |
15/30/75/150 V |
Approximate Consumed Current |
5 mV (200 Ω/V) |
Operating Principle |
Thermocouple type Class |
Class |
JIS C 1102 : 1997 Class 1.0 |
Operating Position |
Horizontal |
Scale Length |
Approximately 135 mm (Deflection Angle: 85°) |
Scale Divisions |
100 for ammeters, 150 for voltmeter |
Overload |
Approximately 1.5 times rated current (or approximate consumed current) |
Operating Frequency Range |
10 Hz to 1 kHz |
Operating Temperature Range |
0 ~ 40 ºC |
Operating Humidity Range |
30 ~ 75% RH |
Storage Temperature Range |
-10 ~ 50 ºC |
Storage Humidity Range |
25 ~ 80% RH |
Linemax |
250 V (Ammeters only) |
Approx. External Dimension |
195 x 170 x 87 mm |
Approx. External Weight |
1.8 kg |
Optional Accessories |
2291 01 Carrying case for ammeters 2292 01 Carrying case for voltmeter B964688 Spare thermocouple |
Features
- Taut-band suspension system eliminates friction and provides good resistance to shock impact.
- For measurements (DC) up to high frequencies
|
|