YOKOGAWA 2406E SERIES OF ANALOG INSULATION TESTER |
YOKOGAWA 2406E SERIES OF ANALOG INSULATION TESTER
The 2406E Analog Insulation Tester:
- Analog models with two and three rating
- AC voltage measurement
- Automatic discharge
- Sky blue EL backlight
- Increased safety (covered battery charger)
Specifications - Model 240631
Rating |
125V/20M~ 25V/5M~ 50V/10M~ |
Effective Measuring Range |
0.001-5M~ 0.005-10M~ 0.01-20M~ |
Central Scale Value |
0.1M~ 0.2M~ 0.5M~ |
AC Voltage Measurement |
0 to 300 V |
Lower Limit |
0.025M~ 0.05M~ 0.125~ |
Rated Current |
1 mA |
Approx. Outer Scale Length |
88 mm |
Discharge Function |
The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width |
120 mm |
Approx. Height |
110 mm |
Approx. Depth |
60 mm |
Approx. Weight |
500 g |
Batteries |
Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240631
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5º max. of angle of inclination) |
External Magnetic Fields |
None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240641
Rating |
125V/20M~ 25V/5M~ 50V/10M~ |
Effective Measuring Range |
0.001-5M~ 0.005-10M~ 0.01-20M~ |
Central Scale Value |
0.1M~ 0.2M~ 0.5M~ |
AC Voltage Measurement |
0 to 300 V |
Lower Limit |
0.025M~ 0.05M~ 0.125~ |
Rated Current |
1 mA |
Approx. Outer Scale Length |
88 mm |
Discharge Function |
The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width |
120 mm |
Approx. Height |
110 mm |
Approx. Depth |
60 mm |
Approx. Weight |
500 g |
Batteries |
Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240641
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5º max. of angle of inclination) |
External Magnetic Fields |
None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240632
Rating |
125V/20M~ |
Effective Measuring Range |
0.01-20M~ |
Central Scale Value |
0.5M~ |
AC Voltage Measurement |
0 to 300 V |
Lower Limit |
0.125~ |
Rated Current |
1 mA |
Approx. Outer Scale Length |
88 mm |
Discharge Function |
The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width |
120 mm |
Approx. Height |
110 mm |
Approx. Depth |
60 mm |
Approx. Weight |
500 g |
Batteries |
Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Condtions - Model 240632
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5º max. of angle of inclination) |
External Magnetic Fields |
None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240642
Rating |
250V/50M~ |
Effective Measuring Range |
0.01-50M~ |
Central Scale Value |
1M~ |
AC Voltage Measurement |
0 to 300 V |
Lower Limit |
0.25~ |
Rated Current |
1 mA |
Approx. Outer Scale Length |
88 mm |
Discharge Function |
The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width |
120 mm |
Approx. Height |
110 mm |
Approx. Depth |
60 mm |
Approx. Weight |
500 g |
Batteries |
Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240642
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5º max. of angle of inclination) |
External Magnetic Fields |
None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240633
Rating |
125V/20M~ 250V/50M~ 500V/100M~ |
Effective Measuring Range |
0.01-20M~ 0.01-50M~ 0.05-100M~ |
Central Scale Value |
0.5M~ 1M~ 2M~ |
AC Voltage Measurement |
0 to 600 V |
Lower Limit |
0.125M~ 0.25M~ 0.5~ |
Rated Current |
1 mA |
Approx. Outer Scale Length |
88 mm |
Discharge Function |
The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width |
120 mm |
Approx. Height |
110 mm |
Approx. Depth |
60 mm |
Approx. Weight |
500 g |
Batteries |
Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240633
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5º max. of angle of inclination) |
External Magnetic Fields |
None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240343
Rating |
125V/20M~ 250V/50M~ 500V/100M~ |
Effective Measuring Range |
0.01-20M~ 0.01-50M~ 0.05-100M~ |
Central Scale Value |
0.5M~ 1M~ 2M~ |
AC Voltage Measurement |
0 to 600 V |
Lower Limit |
0.125M~ 0.25M~ 0.5~ |
Rated Current |
1 mA |
Approx. Outer Scale Length |
88 mm |
Discharge Function |
The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width |
120 mm |
Approx. Height |
110 mm |
Approx. Depth |
60 mm |
Approx. Weight |
500 g |
Batteries |
Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240643
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5º max. of angle of inclination) |
External Magnetic Fields |
None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240634
Rating |
1000V/2000M~ 250V/50M~ 500V/100M~ |
Effective Measuring Range |
0.01-50M~ 0.05-100M~ 1-2000M~ |
Central Scale Value |
1M~ 2M~ 50M~ |
AC Voltage Measurement |
0 to 600 V |
Lower Limit |
0.25M~ 0.5M~ 1~ |
Rated Current |
1 mA |
Approx. Outer Scale Length |
88 mm |
Discharge Function |
The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width |
120 mm |
Approx. Height |
110 mm |
Approx. Depth |
60 mm |
Approx. Weight |
500 g |
Batteries |
Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Condtions - Model 240634
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5º max. of angle of inclination) |
External Magnetic Fields |
None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - 240644
Rating |
1000V/2000M~ 250V/50M~ 500V/100M~ |
Effective Measuring Range |
0.01-50M~ 0.05-100M~ 1-2000M~ |
Central Scale Value |
1M~ 2M~ 50M~ |
AC Voltage Measurement |
0 to 600 V |
Lower Limit |
0.25M~ 0.5M~ 1~ |
Rated Current |
1 mA |
Approx. Outer Scale Length |
88 mm |
Discharge Function |
The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width |
120 mm |
Approx. Height |
110 mm |
Approx. Depth |
60 mm |
Approx. Weight |
500 g |
Batteries |
Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240644
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5º max. of angle of inclination) |
External Magnetic Fields |
None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240635
Rating |
1000V/2000M~ 250V/500M~ 500V/1000M~ |
Effective Measuring Range |
0.1-500M~ 0.5-1000M~ 1-2000M~ |
Central Scale Value |
10M~ 20M~ 50M~ |
AC Voltage Measurement |
0 to 600 V |
Lower Limit |
0.25M~ 0.5M~ 1~ |
Rated Current |
1 mA |
Approx. Outer Scale Length |
88 mm |
Discharge Function |
The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width |
120 mm |
Approx. Height |
110 mm |
Approx. Depth |
60 mm |
Approx. Weight |
500 g |
Batteries |
Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240635
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5º max. of angle of inclination) |
External Magnetic Fields |
None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Specifications - Model 240645
Rating |
1000V/2000M~ 250V/500M~ 500V/1000M~ |
Effective Measuring Range |
0.1-500M~ 0.5-1000M~ 1-2000M~ |
Central Scale Value |
10M~ 20M~ 50M~ |
AC Voltage Measurement |
0 to 600 V |
Lower Limit |
0.25M~ 0.5M~ 1~ |
Rated Current |
1 mA |
Approx. Outer Scale Length |
88 mm |
Discharge Function |
The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (& |
Approx. Width |
120 mm |
Approx. Height |
110 mm |
Approx. Depth |
60 mm |
Approx. Weight |
500 g |
Batteries |
Six AA (R6P) batteries |
Standard Accessories |
Batteries (Qty- 6) Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long Earth probes and Line Probes (98007) (Qty - 1) User's Manual (Qty - 1)- With probe-housing pocket and neck strap |
Standard Test Conditions - Model 240645
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5º max. of angle of inclination) |
External Magnetic Fields |
None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. | |
|