HT INDUSTRIAL AUTOMATION LIMITED

 
YOKOGAWA 2406E SERIES OF ANALOG INSULATION TESTER

YOKOGAWA 2406E SERIES OF ANALOG INSULATION TESTER

The 2406E Analog Insulation Tester:

  • Analog models with two and three rating
  • AC voltage measurement
  • Automatic discharge
  • Sky blue EL backlight
  • Increased safety (covered battery charger)

Specifications - Model 240631

Rating

125V/20M~
25V/5M~
50V/10M~

Effective Measuring Range

0.001-5M~
0.005-10M~
0.01-20M~

Central Scale Value

0.1M~
0.2M~
0.5M~

AC Voltage Measurement

0 to 300 V

Lower Limit

0.025M~
0.05M~
0.125~

Rated Current

1 mA

Approx. Outer Scale Length

88 mm

Discharge Function

The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&

Approx. Width

120 mm

Approx. Height

110 mm

Approx. Depth

60 mm

Approx. Weight

500 g

Batteries

Six AA (R6P) batteries

Standard Accessories

Batteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

Standard Test Conditions - Model 240631

Ambient Temperature/Humidity Ranges

23 ±5 /45-75% RH

Position of Use

Horizontal (5º max. of angle of inclination)

External Magnetic Fields

None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions

Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications - Model 240641

Rating

125V/20M~
25V/5M~
50V/10M~

Effective Measuring Range

0.001-5M~
0.005-10M~
0.01-20M~

Central Scale Value

0.1M~
0.2M~
0.5M~

AC Voltage Measurement

0 to 300 V

Lower Limit

0.025M~
0.05M~
0.125~

Rated Current

1 mA

Approx. Outer Scale Length

88 mm

Discharge Function

The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&

Approx. Width

120 mm

Approx. Height

110 mm

Approx. Depth

60 mm

Approx. Weight

500 g

Batteries

Six AA (R6P) batteries

Standard Accessories

Batteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

Standard Test Conditions - Model 240641

Ambient Temperature/Humidity Ranges

23 ±5 /45-75% RH

Position of Use

Horizontal (5º max. of angle of inclination)

External Magnetic Fields

None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions

Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications - Model 240632

Rating

125V/20M~

Effective Measuring Range

0.01-20M~

Central Scale Value

0.5M~

AC Voltage Measurement

0 to 300 V

Lower Limit

0.125~

Rated Current

1 mA

Approx. Outer Scale Length

88 mm

Discharge Function

The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&

Approx. Width

120 mm

Approx. Height

110 mm

Approx. Depth

60 mm

Approx. Weight

500 g

Batteries

Six AA (R6P) batteries

Standard Accessories

Batteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

Standard Test Condtions - Model 240632

Ambient Temperature/Humidity Ranges

23 ±5 /45-75% RH

Position of Use

Horizontal (5º max. of angle of inclination)

External Magnetic Fields

None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions

Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications - Model 240642

Rating

250V/50M~

Effective Measuring Range

0.01-50M~

Central Scale Value

1M~

AC Voltage Measurement

0 to 300 V

Lower Limit

0.25~

Rated Current

1 mA

Approx. Outer Scale Length

88 mm

Discharge Function

The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&

Approx. Width

120 mm

Approx. Height

110 mm

Approx. Depth

60 mm

Approx. Weight

500 g

Batteries

Six AA (R6P) batteries

Standard Accessories

Batteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

Standard Test Conditions - Model 240642

Ambient Temperature/Humidity Ranges

23 ±5 /45-75% RH

Position of Use

Horizontal (5º max. of angle of inclination)

External Magnetic Fields

None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions

Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications - Model 240633

Rating

125V/20M~
250V/50M~
500V/100M~

Effective Measuring Range

0.01-20M~
0.01-50M~
0.05-100M~

Central Scale Value

0.5M~
1M~
2M~

AC Voltage Measurement

0 to 600 V

Lower Limit

0.125M~
0.25M~
0.5~

Rated Current

1 mA

Approx. Outer Scale Length

88 mm

Discharge Function

The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&

Approx. Width

120 mm

Approx. Height

110 mm

Approx. Depth

60 mm

Approx. Weight

500 g

Batteries

Six AA (R6P) batteries

Standard Accessories

Batteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

Standard Test Conditions - Model 240633

Ambient Temperature/Humidity Ranges

23 ±5 /45-75% RH

Position of Use

Horizontal (5º max. of angle of inclination)

External Magnetic Fields

None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions

Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications - Model 240343

Rating

125V/20M~
250V/50M~
500V/100M~

Effective Measuring Range

0.01-20M~
0.01-50M~
0.05-100M~

Central Scale Value

0.5M~
1M~
2M~

AC Voltage Measurement

0 to 600 V

Lower Limit

0.125M~
0.25M~
0.5~

Rated Current

1 mA

Approx. Outer Scale Length

88 mm

Discharge Function

The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&

Approx. Width

120 mm

Approx. Height

110 mm

Approx. Depth

60 mm

Approx. Weight

500 g

Batteries

Six AA (R6P) batteries

Standard Accessories

Batteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

Standard Test Conditions - Model 240643

Ambient Temperature/Humidity Ranges

23 ±5 /45-75% RH

Position of Use

Horizontal (5º max. of angle of inclination)

External Magnetic Fields

None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions

Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications - Model 240634

Rating

1000V/2000M~
250V/50M~
500V/100M~

Effective Measuring Range

0.01-50M~
0.05-100M~
1-2000M~

Central Scale Value

1M~
2M~
50M~

AC Voltage Measurement

0 to 600 V

Lower Limit

0.25M~
0.5M~
1~

Rated Current

1 mA

Approx. Outer Scale Length

88 mm

Discharge Function

The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&

Approx. Width

120 mm

Approx. Height

110 mm

Approx. Depth

60 mm

Approx. Weight

500 g

Batteries

Six AA (R6P) batteries

Standard Accessories

Batteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

Standard Test Condtions - Model 240634

Ambient Temperature/Humidity Ranges

23 ±5 /45-75% RH

Position of Use

Horizontal (5º max. of angle of inclination)

External Magnetic Fields

None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions

Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications - 240644

Rating

1000V/2000M~
250V/50M~
500V/100M~

Effective Measuring Range

0.01-50M~
0.05-100M~
1-2000M~

Central Scale Value

1M~
2M~
50M~

AC Voltage Measurement

0 to 600 V

Lower Limit

0.25M~
0.5M~
1~

Rated Current

1 mA

Approx. Outer Scale Length

88 mm

Discharge Function

The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&

Approx. Width

120 mm

Approx. Height

110 mm

Approx. Depth

60 mm

Approx. Weight

500 g

Batteries

Six AA (R6P) batteries

Standard Accessories

Batteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

Standard Test Conditions - Model 240644

Ambient Temperature/Humidity Ranges

23 ±5 /45-75% RH

Position of Use

Horizontal (5º max. of angle of inclination)

External Magnetic Fields

None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions

Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications - Model 240635

Rating

1000V/2000M~
250V/500M~
500V/1000M~

Effective Measuring Range

0.1-500M~
0.5-1000M~
1-2000M~

Central Scale Value

10M~
20M~
50M~

AC Voltage Measurement

0 to 600 V

Lower Limit

0.25M~
0.5M~
1~

Rated Current

1 mA

Approx. Outer Scale Length

88 mm

Discharge Function

The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&

Approx. Width

120 mm

Approx. Height

110 mm

Approx. Depth

60 mm

Approx. Weight

500 g

Batteries

Six AA (R6P) batteries

Standard Accessories

Batteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

Standard Test Conditions - Model 240635

Ambient Temperature/Humidity Ranges

23 ±5 /45-75% RH

Position of Use

Horizontal (5º max. of angle of inclination)

External Magnetic Fields

None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions

Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

Specifications - Model 240645

Rating

1000V/2000M~
250V/500M~
500V/1000M~

Effective Measuring Range

0.1-500M~
0.5-1000M~
1-2000M~

Central Scale Value

10M~
20M~
50M~

AC Voltage Measurement

0 to 600 V

Lower Limit

0.25M~
0.5M~
1~

Rated Current

1 mA

Approx. Outer Scale Length

88 mm

Discharge Function

The tester automatically begins discharge when you turn off the MEAS switch. The pointer swings if there is any residual voltage in the circuit under test. You can make sure discharge is complete by checking that the pointer swings back to the infinite (&

Approx. Width

120 mm

Approx. Height

110 mm

Approx. Depth

60 mm

Approx. Weight

500 g

Batteries

Six AA (R6P) batteries

Standard Accessories

Batteries (Qty- 6)
Carrying case (B9075MU) (Qty -1) Earth probe (blake); approx. 1 m long
Earth probes and Line Probes (98007) (Qty - 1)
User's Manual (Qty - 1)- With probe-housing pocket and neck strap

Standard Test Conditions - Model 240645

Ambient Temperature/Humidity Ranges

23 ±5 /45-75% RH

Position of Use

Horizontal (5º max. of angle of inclination)

External Magnetic Fields

None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)

Tolerance Mentioned Conditions

Resistance measurement: First effective measuring range = ±5% of reading
Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max.

#
copyright 2009-2021  HT INDUSTRIAL AUTOMATION LIMITED