YOKOGAWA MY10 SERIES OF ANALOG TESTERS |
YOKOGAWA MY10 SERIES OF ANALOG TESTERS
- Analog models with single rating
MY10-01:125V/20MΩ MY10-02:250V/50MΩ MY10-03:500V/100MΩ MY10-04:500V/1000MΩ MY10-05:1000V/2000MΩ
- AC voltage measurement
- Automatic discharge
- A wide choice of accessories-Designed for shared use with the MY40
Specifications - Model MY10-01
Rating |
125V/20MΩ |
Effective Measuring Range |
0.01-20MΩ |
Central Scale Value |
0.5MΩ |
AC Voltage Measurement |
0 to 250 V |
Lower Limit |
0.125MΩ |
Rated Current |
1-1.2 mA |
Approx. Overall Scale Length |
107 mm |
Battery Life |
Approx. 10 hours when continuously operated on manganese - oxide batteries with the pointer pointing to the central scale value. |
Batteries |
Four AA (R6P) batteries |
Approx. Width |
125 mm |
Approx. Height |
103 mm |
Approx. Depth |
53 mm |
Approx. Weight |
500 g |
Compliance |
EN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use) |
Standard Accessories |
Batteries (Qty - 4) Earth Probe (98002) (Qty - 1) Line Probe (98001) (Qty - 1) Protection Cover (93013) (Qty - 1) Shoulder Strap (99005) (Qty - 1) User's Manual (Qty - 1) |
Standard Test Conditions - Model MY10-01
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5° max. of angle of inclination) |
Battery Voltage |
Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Additional Functions - Model MY10-01
- Automatic discharge function
- If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.
- When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.
- Battery check (BAT mark on the scale plate)
Specifications - Model MY10-02
Rating |
250V/50MΩ |
Effective Measuring Range |
0.01-50MΩ |
Central Scale Value |
1MΩ |
AC Voltage Measurement |
0 to 300 V |
Lower Limit |
0.25MΩ |
Rated Current |
1-1.2 mA |
Approx. Overall Scale Length |
107 mm |
Battery Life |
Approx. 10 hours when continuously operated on manganese - oxide batteries with the pointer pointing to the central scale value. |
Batteries |
Four AA (R6P) batteries |
Approx. Width |
125 mm |
Approx. Height |
103 mm |
Approx. Depth |
53 mm |
Approx. Weight |
500 g |
Compliance |
EN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use) |
Standard Accessories |
Batteries (Qty - 4) Earth Probe (98002) (Qty - 1) Line Probe (98001) (Qty - 1) Protection Cover (93013) (Qty - 1) Shoulder Strap (99005) (Qty - 1) User's Manual (Qty - 1) |
Standard Test Conditions - Model MY10-02
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5° max. of angle of inclination) |
Battery Voltage |
Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Additional Functions - Model MY10-02
- Automatic discharge function
- If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.
- When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.
- Battery check (BAT mark on the scale plate)
Specifications - Model MY10-03
Rating |
500V/100MΩ |
Effective Measuring Range |
0.05-100MΩ |
Central Scale Value |
2MΩ |
AC Voltage Measurement |
0 to 500 V |
Lower Limit |
0.5MΩ |
Rated Current |
1-1.2 mA |
Approx. Overall Scale Length |
107 mm |
Battery Life |
Approx. 10 hours when continuously operated on manganese - oxide batteries with the pointer pointing to the central scale value. |
Batteries |
Four AA (R6P) batteries |
Approx. Width |
125 mm |
Approx. Height |
103 mm |
Approx. Depth |
53 mm |
Approx. Weight |
500 g |
Compliance |
EN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use) |
Standard Accessories |
Batteries (Qty - 4) Earth Probe (98002) (Qty - 1) Line Probe (98001) (Qty - 1) Protection Cover (93013) (Qty - 1) Shoulder Strap (99005) (Qty - 1) User's Manual (Qty - 1) |
Standard Test Conditions - Model MY10-03
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5° max. of angle of inclination) |
Battery Voltage |
Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Additional Functions - Model MY10-03
- Automatic discharge function
- If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.
- When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.
- Battery check (BAT mark on the scale plate)
Specifications - Model MY10-04
Rating |
500V/1000MΩ |
Effective Measuring Range |
0.5-1000MΩ |
Central Scale Value |
20MΩ |
AC Voltage Measurement |
0 to 500 V |
Lower Limit |
1MΩ |
Rated Current |
0.5-0.6 mA |
Approx. Overall Scale Length |
107 mm |
Battery Life |
Approx. 10 hours when continuously operated on manganese - oxide batteries with the pointer pointing to the central scale value. |
Batteries |
Four AA (R6P) batteries |
Approx. Width |
125 mm |
Approx. Height |
103 mm |
Approx. Depth |
53 mm |
Approx. Weight |
500 g |
Compliance |
EN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use) |
Standard Accessories |
Batteries (Qty - 4) Earth Probe (98002) (Qty - 1) Line Probe (98001) (Qty - 1) Protection Cover (93013) (Qty - 1) Shoulder Strap (99005) (Qty - 1) User's Manual (Qty - 1) |
Standard Test Conditions - Model MY10-04
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5° max. of angle of inclination) |
Battery Voltage |
Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Additional Functions - Model MY10-04
- Automatic discharge function
- If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.
- When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.
- Battery check (BAT mark on the scale plate)
Specifications - Model MY10-05
Rating |
1000V/2000MΩ |
Effective Measuring Range |
1-2000MΩ |
Central Scale Value |
50MΩ |
AC Voltage Measurement |
0 to 500 V |
Lower Limit |
2MΩ |
Rated Current |
0.5-0.6 mA |
Approx. Overall Scale Length |
107 mm |
Battery Life |
Approx. 10 hours when continuously operated on manganese - oxide batteries with the pointer pointing to the central scale value. |
Batteries |
Four AA (R6P) batteries |
Approx. Width |
125 mm |
Approx. Height |
103 mm |
Approx. Depth |
53 mm |
Approx. Weight |
500 g |
Compliance |
EN61010-1:1993; EN61010-2-31:1995 (Overvoltage Category III, Pollution Degree 2 installations for indoor use) |
Standard Accessories |
Batteries (Qty - 4) Earth Probe (98002) (Qty - 1) Line Probe (98001) (Qty - 1) Protection Cover (93013) (Qty - 1) Shoulder Strap (99005) (Qty - 1) User's Manual (Qty - 1) |
Standard Test Conditions - Model MY10-05
Ambient Temperature/Humidity Ranges |
23 ±5 /45-75% RH |
Position of Use |
Horizontal (5° max. of angle of inclination) |
Battery Voltage |
Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.) |
Tolerance Mentioned Conditions |
Resistance measurement: First effective measuring range = ±5% of reading Second effective measuring range = ±10% of reading Infinite and zero scale values: 0.7% max. of scale length AC voltage: ±10% of maximum scale value No-load voltage: 130% max. of rated voltage Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range Short-circuit current: 12 mA max. |
Additional Functions - Model MY10-05
- Automatic discharge function
- If the object under test remains electrified after the MEAS switch is turned off, the tester lets you know by turning on the LED lamp. If you leave the tester connected to the electrified object, the tester automatically begins to discharge electricity and then finishes discharging-the LED lamp comes on and then goes out.
- When the object under test is capacitive and electrified, the tester lets you know by turning on the LED lamp. When left connected to the object, the tester automatically discharges electricity, thus preventing possible electric shock or spike noise at power-on.
- Battery check (BAT mark on the scale plate)
|
|