HT INDUSTRIAL AUTOMATION LIMITED

 
YOKOGAWA CLAMP-ON TESTER FOR AC/DC CURRENT #CL250

YOKOGAWA CLAMP-ON TESTER FOR AC/DC CURRENT #CL250

Clamp-on Testers For AC/DC Current

  • AC/DC current measurements with current ranges up to 2000A
  • AC/DC voltage and resistance measurements
  • DC output
  • 55mm in diameter of measurable conductor
  • Mean value display
  • Sleep function
  • Data hold function
  • Approved for comformity to safety standards EN61010-1, EN61010-2-031, EN61010-2-032 (CAT. III 600 V, CAT. II 1000 V)

Specifications

Description

ACA, DCA, ACV, DCV, OHM, Freq. °C Continuity Check

Method of detection

Mean Value

Display

LCD (Digital display: 3999 counts)

DC Current Range

400/2000A

DC Current Resolution

0.1A

Response Time

Approx. 2 seconds

Range Switching

Auto-range (on resistance range)
Manual-range (on current, voltage range)

Operating temperature and humidity

0 - 40°C, 85% RH or less (no condensation)

Influence of external magnetic field

4A or less at 400 A/m

Influence of conductor position

±(1.5% rdg + 3 dgt) or less

Safety Standard

Conforms EN61010-1, EN61010-2-031, EN61010-2-032

Circuit voltage

1000 Vrms or less

Withstanding voltage

5.55 kV AC for one minute

Power Supply

LR6 x 2
R6P (SUM-3) x 2

Battery Life

Approx. 100 hours (continuous)

Consumed current

Approx. 9 mA

Sleep Function

Automatically powered down in about 10 minutes after the last switch operation

Diameter of measurable conductor

55 mm at maximum

Dimensions

Approx. 105 (W) x 250 (H) x 49 (D) mm

Weight

Approx. 530 g

Accessories

Batteries, carrying case (93034)
Output plug (98012)
Test Lead (98011)
User's manual (IM CL250)

Peak Hold

On all range

Max Hold

On current / Voltage range

Selection Guide

AC Current Range

400/2000A

AC Current Resolution

0.1A

AC Current Frequency characteristics

40~1kHz

AC Current Method of detection

Mean Value

AC Voltage Measurement

O

DC Voltage Measurement

O

Continuity Check Measurement

O

Frequency Measurement

-

Temperature Measurement

-

Recorder output Function

O

Waveform monitor output Function

-

Data hold Function

O

Auto hold Function

-

Peak Hold Function

-

Maximum value memory Function

O

Mean value display Function

-

Filter Function

-

Range Hold Function

(current range)

Auto ZERO Adjust Function

O

Auto power-off Function

Δ

Additional Specification

At 23°C±5°C75%RH or less

Accuracy: ±( % rdg + dgt) = ±(% readout + value of least significant digit)

Parameter

Reference

Accuracy

DC current

400/2000A

1.5+2

AC current

400A/2000A(01000A)

1.5+2 (50/60Hz)

3.0+4 (40500Hz)

5.0+4 (5001kHz)

2000A (10012000A)

3.0+2 (50/60Hz)

DC voltage

400/1000V

1.0+2

AC voltage

400/750V

1.5+2 (50/60Hz)

1.5+4 (401kHz)

Resistance

400/4000Ω

1.5+2 , Beeps at below 50±35Ω (continuity check)

DC output

DC400A (0400mV)

±1.5% rdg ±3mV

DC2000A (0200mV)

±1.5% rdg ±3mV

AC400A (0400mV) AC2000A (0100mV/01000A)

±1.5% rdg ±3mV (50/60Hz)

±3.0% rdg ±3mV (40500Hz)

±5.0% rdg ±3mV (5001kHz)

AC2000A (100.1200mV/10012000A)

±3.0% rdg ±3mV (50/60Hz)

#
copyright 2009-2021  HT INDUSTRIAL AUTOMATION LIMITED