YOKOGAWA CLAMP-ON TESTER FOR AC/DC CURRENT #CL235 |
YOKOGAWA CLAMP-ON TESTER FOR AC/DC CURRENT #CL235
Clamp-on Testers For AC/DC Current
- True RMS display
- AC/DC current measurements with current ranges up to 600A for
- AC and 1000A for DC
- AC/DC voltage, resistance and frequency measurements 33mm in diameter of measurable conductor
- Sleep function
- Data hold function
- Approved for comformity to safety standards EN61010-1,EN61010-2-031, EN61010-2-032 (CAT. III 600 V)
Specifications
|
Description |
True RMS ACA, ACV, DCA, DCV |
|
Method of detection |
True RMS |
|
Display |
LCD (Digital display: 3999 counts) |
|
DC Current Range |
400/1000A |
|
DC Current Resolution |
0.1A |
|
Response Time |
Approx. 2 second |
|
Range Switching |
Auto-range |
|
Data hold |
On all range |
|
Operating temperature and humidity |
0 - 40°C, 90% RH or less (no condensation) |
|
Influence of conductor position |
±2% or less |
|
Safety Standard |
Conforms EN61010-1, EN61010-2-031, EN61010-2-032 |
|
Circuit voltage |
600 Vrms or less |
|
Withstanding voltage |
5.55 kV AC for one minute |
|
Power Supply |
6F22 (006P) 9V x 1 6LR61 x 1 |
|
Battery Life |
Approx. 15 hours (continuous) |
|
Consumed current |
Approx. 15 mA |
|
Sleep Function |
Automatically powered down in about 30 minutes after the last switch operation |
|
Diameter of measurable conductor |
33 mm at maximum |
|
Dimensions |
Approx. 91 (W) x 210 (H) x 40 (D) mm |
|
Weight |
Approx. 450 g |
|
Accessories |
Batteries, carrying case (93032) User's manual (IM CL235) |
|
Peak Hold |
On AC/DC current range, AC/DC voltage range |
Selection Guide
|
AC Current Range |
400/600A |
|
AC Current Resolution |
0.1A |
|
AC Current Frequency characteristics |
40~1kHz |
|
AC Current Method of detection |
True RMS |
|
AC Voltage Measurement |
O |
|
DC Voltage Measurement |
O |
|
Continuity Check Measurement |
O |
|
Frequency Measurement |
O |
|
Temperature Measurement |
- |
|
Recorder output Function |
- |
|
Waveform monitor output Function |
- |
|
Data hold Function |
O |
|
Auto hold Function |
- |
|
Peak Hold Function |
O |
|
Maximum value memory Function |
- |
|
Mean value display Function |
O |
|
Filter Function |
- |
|
Range Hold Function |
- |
|
Auto ZERO Adjust Function |
O |
|
Auto power-off Function |
Δ |
Additional Specification
|
At 23°C±5°C,75%RH or less |
|
Accuracy: ±( % rdg + dgt) = ±(% readout + value of least significant digit) |
|
Parameter |
Reference |
Accuracy |
|
AC current |
400/600A |
1.5+5 (50/60Hz) |
|
|
3.5+5 (40~1kHz) |
|
DC current |
400/1000A |
1.0+5 |
|
AC voltage |
40/400/600V |
1.5+5 (50/60Hz) |
|
3.5+5 (40~1kHz) |
|
DC voltage |
40/400/600V |
1.0+5 |
|
Crest factor |
|
≦3 |
|
Resistance |
400/4000Ω |
1.0+5 , Beeps at below 20Ω (continuity check) |
|
Frequency |
10~3000Hz |
1.5+5 | |
|