YOKOGAWA CLAMP-ON TESTER FOR AC/DC CURRENT #CL220 |
YOKOGAWA CLAMP-ON TESTER FOR AC/DC CURRENT #CL220
Clamp-on Testers For AC/DC Current
- AC/DC current measurements with current ranges up to 300A
- 24mm in diameter of measurable conductor
- Light weight & compact design
- Mean value display
- Sleep function
- Approved for comformity to safety standards EN61010-1, EN61010-2-032 (CAT. III 300 V)
Specifications
|
Description |
AC/DC Mini Clamp-on |
|
Method of detection |
Mean Value |
|
Display |
LCD (Digital display: 3999 counts) |
|
DC Current Range |
40/300A |
|
DC Current Resolution |
0.01A |
|
Response Time |
Approx. 2 second |
|
Range Switching |
Auto-range |
|
Data hold |
On all range |
|
Operating temperature and humidity |
0 - 40°C, 90% RH or less (no condensation) |
|
Influence of external magnetic field |
1A or less at 400 A/m |
|
Influence of conductor position |
±(2% rdg + 5dgt) or less |
|
Safety Standard |
Conforms EN61010-1, EN61010-2-031, EN61010-2-032 |
|
Circuit voltage |
300 Vrms or less |
|
Withstanding voltage |
3.7 kV AC for one minute |
|
Power Supply |
LR-44 x 2 (3V) SR-44 x 2 |
|
Battery Life |
Approx. 11 hours (continuous) |
|
Consumed current |
Approx. 9 mA |
|
Sleep Function |
Automatically powered down in about 5 minutes after the last switch operation |
|
Diameter of measurable conductor |
24 mm at maximum |
|
Dimensions |
Approx. 59 (W) x 147 (H) x 25 (D) mm |
|
Weight |
Approx. 100 g |
|
Accessories |
Batteries, carrying case (93033) User's manual (IM CL235) |
Selection Guide
|
AC Current Range |
40/300A |
|
AC Current Resolution |
0.01A |
|
AC Current Frequency characteristics |
20~1kHz |
|
AC Current Method of detection |
Mean Value |
|
AC Voltage Measurement |
- |
|
DC Voltage Measurement |
- |
|
Continuity Check Measurement |
- |
|
Frequency Measurement |
- |
|
Temperature Measurement |
- |
|
Recorder output Function |
- |
|
Waveform monitor output Function |
- |
|
Data hold Function |
O |
|
Auto hold Function |
- |
|
Peak Hold Function |
- |
|
Maximum value memory Function |
- |
|
Mean value display Function |
- |
|
Filter Function |
- |
|
Range Hold Function |
- |
|
Auto ZERO Adjust Function |
O |
|
Auto power-off Function |
Δ |
Additional Specification
|
At 23°C±5°C,75%RH or less |
|
Accuracy: ±( % rdg + dgt) = ±(% readout + value of least significant digit) |
|
Parameter |
Reference |
Accuracy |
|
DC current |
40A |
1.0+4 |
|
300A(±20~±200A) |
1.5+4 |
|
300A(±200~±300A) |
3.0 |
|
AC current |
40A |
1.0+4 (50/60Hz) |
|
2.5+4 (20~1kHz) |
|
300A(20~200A) |
1.5+4 (50/60Hz) |
|
2.5+4 (20~1kHz) |
|
300A(200~300A) |
3.5 (50/60Hz) |
|
4.0 (20~1kHz) | |
|