YOKOGAWA ACA, ACV, DCV, OHM, CONTINUITY CHECK CLAMP-ON TESTER FOR AC CURRENT #CL150 |
YOKOGAWA ACA, ACV, DCV, OHM, CONTINUITY CHECK CLAMP-ON TESTER FOR AC CURRENT #CL150
ACA, ACV, DCV, OHM, Continuity Check - Clamp-on Tester for AC Current
- AC current measurement with current ranges up to 2000A
- AC/DC voltage and resistance measurements
- 54mm in diameter of measurable conductor
- Mean value display
- DC output function
- Data hold function
- Sleep function
- Approved for comformity to safety standards EN61010-1,
- EN61010-2-031, EN61010-2-032 (CAT. m 600 V, CAT. II1000 V)
Specifications
|
Display (LCD, Digital Counts) |
3999 |
|
AC Current Accuracy (400A Reference) |
1.0+3(50/60Hz) 2.0+3(40~1kHz) |
|
AC Current Accuracy (2000A Reference, 0~1500A) |
1.0+3(50/60Hz) 3.0+3(40~1kHz) |
|
AC Voltage Accuracy (40/400V/750V Reference) |
1.0+2(50/60Hz) 1.5+3(40~1kHz) |
|
DC Voltage Accuracy (40/400V/1000V Reference) |
1.0+2 |
|
Resistance Accuracy (400/4k/40k/400kΩ reference) |
1.5+2, Beeps at below 50± 35Ω (continuity check) |
|
DC Output Accuracy (400A, 0~400mV Reference) |
۫.5% rdg ± 0.5mV (50/60Hz) ۬.5% rdg ± 0.5mV (40~1kHz) |
|
Method of detection |
Mean Value |
|
Response Time |
Approx. 2 seconds |
|
Range Switching |
Manual-range (on AC current range) / Auto-range (on AC voltage range, resistance range) |
|
Data hold |
On all range |
|
Operating temperature and humidity |
0-40°C, 85% RH or less (no condensation) |
|
Influence of external magnetic field |
1A or less at 400A/m |
|
Influence of conductor position |
± (2% rdg + 3dgt) or less |
|
Safety Standard |
Conforms EN 61010-1, EN61010-2-031, EN61010-2-032 |
|
Circuit voltage |
1000Vrms or less |
|
Withstanding voltage |
5.55kV AC for one minute |
|
Power Supply |
R6P(SUM-3)x2 or LR6x2 |
|
Battery Life1 |
150 hours |
|
Consumed current |
Approx. 5mA |
|
Sleep Function |
Automatically powered down in about 10 minutes after the last switch operation |
|
Diameter of measurable conductor |
54mm at maximum |
|
Dimensions |
Approx. 105(W)x247(H)x49(D)mm |
|
Weight (Approx.) |
470g |
|
Accessories |
User's manual (IM CL150), batteries, carrying case (93034) |
|
Order Notes |
Each item selected MUST be ordered as a separate line item. |
|
Product Notes |
All Clamp-on Meters include Test Leads (where applicable) and a carrying case. |
|
1 Approximate, continuous | |
|
Selection Guide
|
AC Current Range |
400/2000A |
|
AC Current Resolution |
0.1A |
|
AC Current Frequency characteristics |
40~1kHz |
|
AC Current Method of detection |
Mean Value |
|
AC Voltage Measurement |
O |
|
DC Voltage Measurement |
O |
|
Continuity Check Measurement |
O |
|
Frequency Measurement |
- |
|
Temperature Measurement |
- |
|
Recorder output Function |
O |
|
Waveform monitor output Function |
- |
|
Data hold Function |
O |
|
Auto hold Function |
- |
|
Peak Hold Function |
O |
|
Maximum value memory Function |
- |
|
Mean value display Function |
- |
|
Filter Function |
- |
|
Range Hold Function |
O (current range) |
|
Auto ZERO Adjust Function |
- |
|
Auto power-off Function |
O Sleep function (power-down) | |
|