YOKOGAWA 732 SERIES DIGITAL MULTIMETERS |
YOKOGAWA 732 SERIES DIGITAL MULTIMETERS
3.5 digits (4,300-count), Mean value type Measurement Functions: Voltage, Current, Resistance, Continuity Check, Diode Test, Capacitance Features: Auto hold, Auto power-off
Specifications - Model 73201/R
|
Display |
4300-count digital reading |
|
|
DC Voltage Accuracy1 |
0.75% + 1 |
|
|
AC Voltage Accuracy2 |
1% + 5 |
|
|
Additional Functions |
Auto hold, overvoltage and current warning |
|
|
Features |
- Accuracy 0.5% at DC voltage and 4300 count digital Display
- Compact size & ideal for carrying
- Large display for easy viewing
- Safe design allows measurement in excess of 20A
- Auto hold function
- 3 year warranty
|
|
|
Operating Temp and Humidity |
0 to 50°C; 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
|
|
Power Supply |
Two AAA (LR03 or R03) dry cells |
|
|
Battery Life |
Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) |
|
|
Dimensions |
74 (W) x 155 (H) x 31 (D) mm |
|
|
Weight |
Approx. 240 g (including batteries) |
|
|
Compliance with Standards |
Safety EN61010-1 (1995) + Amend; EN61010-2-031 (1995) (600 V, CAT II; 300 V, CAT III; contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997) |
|
|
Standard Accessories |
AAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1 |
|
|
Optional Accessories |
Carrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007) |
1 40V - 600V Range 2 4V - 600V Range
Specifications - Model 73202/R
|
Display |
4300-count digital reading |
|
|
DC Voltage Accuracy1 |
0.5% + 1 |
|
|
AC Voltage Accuracy2 |
1% + 5 |
|
|
Additional Functions |
Auto hold, overvoltage and current warning |
|
|
Features |
- Accuracy 0.5% at DC voltage and 4300 count digital Display
- Compact size & ideal for carrying
- Large display for easy viewing
- Safe design allows measurement in excess of 20A
- Auto hold function
- 3 year warranty
|
|
|
Operating Temp and Humidity |
0 to 50°C; 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
|
|
Power Supply |
Two AAA (LR03 or R03) dry cells |
|
|
Battery Life |
Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) |
|
|
Dimensions |
74 (W) x 155 (H) x 31 (D) mm |
|
|
Weight |
Approx. 240 g (including batteries) |
|
|
Compliance with Standards |
Safety EN61010-1 (1995) + Amend; EN61010-2-031 (1995) (600 V, CAT II; 300 V, CAT III; contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997) |
|
|
Standard Accessories |
AAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1 |
|
|
Optional Accessories |
Carrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007) |
1 40V - 600V Range 2 4V - 600V Range
Specifications - Model 73203/R
|
Display |
4300-count digital reading |
|
|
DC Voltage Accuracy1 |
0.5% + 1 |
|
|
AC Voltage Accuracy2 |
0.75% + 1 |
|
|
Additional Functions |
Auto hold, overvoltage and current warning |
|
|
Features |
- Accuracy 0.5% at DC voltage and 4300 count digital Display
- Compact size & ideal for carrying
- Large display for easy viewing
- Safe design allows measurement in excess of 20A
- Auto hold function
- 3 year warranty
|
|
|
Operating Temp and Humidity |
0 to 50°C; 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
|
|
Power Supply |
Two AAA (LR03 or R03) dry cells |
|
|
Battery Life |
Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) |
|
|
Dimensions |
74 (W) x 155 (H) x 31 (D) mm |
|
|
Weight |
Approx. 240 g (including batteries) |
|
|
Compliance with Standards |
Safety EN61010-1 (1995) + Amend; EN61010-2-031 (1995) (600 V, CAT II; 300 V, CAT III; contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997) |
|
|
Standard Accessories |
AAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1 |
|
|
Optional Accessories |
Carrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007) |
1 40V - 600V Range 2 4V - 600V Range
Specifications - Model 73204/R
|
Display |
4300-count digital reading |
|
|
DC Voltage Accuracy1 |
0.3% + 1 |
|
|
AC Voltage Accuracy2 |
0.75% + 1 |
|
|
Additional Functions |
Auto hold, overvoltage and current warning |
|
|
Features |
- Accuracy 0.5% at DC voltage and 4300 count digital Display
- Compact size & ideal for carrying
- Large display for easy viewing
- Safe design allows measurement in excess of 20A
- Auto hold function
- 3 year warranty
|
|
|
Operating Temp and Humidity |
0 to 50°C; 80% RH or less at 0°C to 40°C, or 70% RH or less at 40°C to 50°C (no condensation) |
|
|
Power Supply |
Two AAA (LR03 or R03) dry cells |
|
|
Battery Life |
Approx. 600 hours (for continuous DC voltage measurement with alkaline cells) |
|
|
Dimensions |
74 (W) x 155 (H) x 31 (D) mm |
|
|
Weight |
Approx. 240 g (including batteries) |
|
|
Compliance with Standards |
Safety EN61010-1 (1995) + Amend; EN61010-2-031 (1995) (600 V, CAT II; 300 V, CAT III; contamination level 2, indoor use: 73201,73202, 73203) EMC EMI: EN55011 (1991) (Class B, Group 1) EMS: EN50082-1 (1997) |
|
|
Standard Accessories |
AAA (LR03/R03) dry cells (built in): 2 Instruction manual: 1 Spare fuse F02 (15 A/250 V): 1 Spare fuse F05 (500 mA/250 V): 1 Test lead set (RD031) :1 |
|
|
Optional Accessories |
Carrying Case (hard) Hoses the DMM and test leads (B9648GB) Rubber Case for DMM (93007) |
1 40V - 600V Range 2 4V - 600V Range |
|